期刊文献+

煤直接液化减压塔进料球阀失效分析及修复 被引量:2

Failure Analysis and Repair of Feedstock Ball Valve in Direct Coal Liquefaction Vacuum Tower
下载PDF
导出
摘要 介绍了煤直接液化工艺流程及其特点。根据减压塔进料球阀的工作参数和功能作用,比照其失效形貌,分析了该球阀发生磨损失效的原因,制定了相应的拆解和修复方案。对修复后的球阀进行检查和试验,以满足标准规范的要求。最后对该球阀的优化运行给出了建议。 The technological process and characteristics of the direct coal liquefaction are introduced. In consideration of the working parameters and functions as well as the failure morphology of the feedstock ball valve in the vacuum tower, the reason of the wear failure is analyzed and the corresponding disassembly and repair scheme are proposed. Then the examinations and tests are performed to meet the requirements of the standards. At last, the advices on the optimal operation are given.
出处 《化工装备技术》 CAS 2016年第3期63-66,共4页 Chemical Equipment Technology
关键词 煤直接液化 球阀 失效分析 修复 磨损 表面硬化 减压塔 Direct coal liquefaction Ball valve Failure analysis Repair Wear Surface hardening Vacuum tower
  • 相关文献

参考文献2

二级参考文献2

  • 1王渭,明友.壳牌粉煤气化装置中特种阀的选型和应用[A].第六届全国阀门与管道学术会议论文集[C].2009.
  • 2熊焱军,郭晓镭,黄万杰,赵锦超,王渭,龚欣.新型煤粉流量调节阀性能研究[J].自动化仪表,2009,30(6):4-7. 被引量:11

共引文献7

同被引文献24

引证文献2

二级引证文献2