摘要 建立了快速检测白酒中15种邻苯二甲酸酯类塑化剂的离子迁移谱法。对主要参数进行优化,选择源压力2500 V、迁移管温度为170℃、离子栅门为90μs、离子栅门压力为45 V时进行测定。样品简单稀释后进样,30 ms内即可出峰,1 min可获得6组平行数据,RSD为6.5%-10.2%。利用此方法对10种白酒和5种红酒盲样进行测定,成功筛查出了含有塑化剂的样品,总筛查时间在30 min以内,实现了快速检测的需求。 HPIMS method was successfully established to detect plasticizers in liquor and wine. The optimized source voltage,tube temperature,gate width and gate voltage was 2500 V,180 ℃,90 μs and 45 V,respectively. Signal was rapidly acquired in 30 ms,and 6 parallel data can be captured in 1 min with RSD ranging from 6.5% to 10.2%. The method was used to detect 15 kinds of plasticizers in liquor and wine. The total screening time of these spirits was in 30 min,realizing the rapid demand.
出处 《检验检疫学刊》 2016年第3期18-23,共6页 Journal of Inspection and Quarantine
基金 国家质检总局科技计划项目(2014IK111)
关键词 离子迁移谱 白酒和红酒 快速 塑化剂 Ion Mobility Spectrometry Liquor and Wine Rapid Plasticizers