摘要 针对某款变频新国标机器匹配过程中出现制冷能力不稳定、蒸发器没有进行充分换热的情况,主要从以下两方面进行优化,解决了以上问题:1通过Wei sman流型图定量分析确定了分流器要达到雾状流所需要的孔径;2通过布热电偶数据判断每一路的蒸发情况来最终确定U管数量及分流毛细管长度,保证蒸发器充分换热。最终确定该款变频新国标机器采用D5蒸发器、¢4孔径分流器的方案,实现能力达到稳定且APF能够满足新国标3.35的要求。 In view of the situation that the refrigeration performance is not stable and the evaporator does not have enough heat exchange in the matching process of inverter air-condition,the optimization in the new national standard is carried out from the following two aspects to solve the above problems : 1 Determine the aperture when the refrigerant cross the divider and turn to mist flow by the quantitative analysis of Wei sman flow pattern figure; 2 to guarantee the evaporator heat exchange, we use the temperature-measuring thermocouple data to determine evaporation situation of each pipeline to finally confirm the quantity of U tube and the length of capillary. Finally, it determines the scheme of D5 evaporator and ¢ 4 aperture divider in the new national standard inverter air-condition, and ensure that the refrigeration performance is stable and APF meets the requirements of the new national standard 3.35.
出处 《日用电器》 2016年第6期26-29,共4页 ELECTRICAL APPLIANCES
关键词 制冷性能 蒸发器 分流器 射流环孔径 WEI sman流型图 流路优化 refrigeration performance evaporator divider jet device aperture wei sman flow pattern figure flow path optimization
  • 相关文献

参考文献4

二级参考文献8

  • 1高利伟.分液器的原理和应用[J].低温与特气,2007,25(4):9-10. 被引量:4
  • 2合肥通用机械研究院.GB17758-1999单元式空气调节机试验方法[S].北京:中国标准出版社,1999.
  • 3Wu W,Ding G.L,Zheng Y.X. Principle of designing fin-and-tube heat exchanger with smaller tube for air conditioner[A].West Lafayette,Indiana,USA,2012.
  • 4Ding G.L,Ren T,Wu W. Developing low charge R290 room air conditioner by using smaller diameter copper tubes[A].Delft,The Netherlands,2012.
  • 5董续君;黄辉;张桃.空调器中制冷分流器及其组件的性能研究[A],2005.
  • 6J.Weisman,D.Duncan,J.Gibson. Effects of fluid properties and pipe diameter on two-phase flow patterns in horizontal lines[J].{H}International Journal of Multiphase Flow,1979,(06):437-462.
  • 7李泽芳,苏庆勇.单元式空调机节流毛细管分液头的改进与实验[J].装备制造技术,2008(3):18-19. 被引量:8
  • 8崔勇,孙宗鑫,陈蕴光,徐正本,袁秀玲,冯军,金德毅.热力膨胀阀与电子膨胀阀对分液性能影响的比较[J].制冷,2003,22(2):11-14. 被引量:3

共引文献52

同被引文献20

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部