期刊文献+

石墨烯/聚嘧啶复合膜修饰电极用于甲基对硫磷的电化学测定 被引量:2

Graphene/polypyrimidine composite film modified electrode for electrochemical determination of methyl parathion
下载PDF
导出
摘要 采用一步电沉积法制备了石墨烯/聚嘧啶复合膜修饰电极.利用循环伏安法和方波伏安法研究了甲基对硫磷在该复合膜电极上的电化学行为.结果表明,该复合膜对甲基对硫磷具有灵敏度高、响应速度快等特点.在最佳条件下,甲基对硫磷的峰电流响应与其浓度在0.000 3-2.5μmol/L范围内呈现良好的线性关系,检测限为0.05nmol/L.该石墨烯/聚嘧啶复合膜修饰玻碳电极也表现出良好的稳定性、重现性和抗干扰能力,并可用于实际样品的检测。 A modified electrode was fabricated by one-step electrodeposition of graphene/polypyrimidine composite film on glass carbon electrode surface(rGO/pAMP/GCE).Electrochemcial behaviors of methyl parathion(MP)on rGO/pAMP/GCE were investigated with Cyclic Voltammetry(CV)and Square Wave Voltammetry(SWV).The results indicated that the rGO/pAMP composite film possesses good sensitivity and fast response for MP.Under the optimal conditions,current response plotted with MP concentration was line in 0.000 3-2.5μmol/L with a detection limit of 0.05nmol/L.The rGO/pAMP/GCE was employed for MP determination in real samples because of its high stability,reproducibility and anti-interference.
出处 《华中师范大学学报(自然科学版)》 CAS 北大核心 2016年第4期565-570,587,共7页 Journal of Central China Normal University:Natural Sciences
基金 国家自然科学基金资助项目(21561011) 湖北民族学院科研创新团队项目(MY2014T004)
关键词 一步电沉积 石墨烯 4-氨基-2-巯基嘧啶 修饰电极 甲基对硫磷 one-step electrodeposition graphene 4-amino-2-mercaptopyrimidine modified electrode methyl parathion
  • 相关文献

参考文献20

  • 1MANZANILLA-CANO J A, REYES-SALAS E O, BARCELO- QUINTAL M H. Electrochemical elimination of the pesticide methylparathion in an aqueous medium[J]. International Journal of Environmental Analytical Chemistry, 1999, 75(4): 387-405.
  • 2HOU J, TIAN Z, XIE H, et al. A fluorescence resonance energy transfer sensor based on quaternized carbon dots and Ellman's test for ultrasensitive detection of diehlorvos[J]. Sensors and Actuators B: Chemical, 2016, 232: 477-483.
  • 3ZHOU Q, MENG G, WU N, et al. Dipping into a drink: Basil-seed supported silver nanoparticles as surface-enhanced Raman scattering substrates for toxic molecule detection[J]. Sensors and Actuators B: Chemical, 2016, 223: 447-452.
  • 4CINELLI G, AVINO P, NOTARDONATO I, et al. Ultra- sound vortex-assisted dispersive liquid-liquid microextraction coupled with gas chromatography with a nitrogen - phos- phorus detector for sitrtultaneous and rapid determination of organophosphorus pesticides and triazines in winc[J]. Ana- lytical Methods, 2014, 6(3): 782-790.
  • 5WANG Q, ZHANG X, XU Z, et al. Simultaneous determi- nation of three trace organophosphorus pesticide residues in vegetables using molecularly imprinted solid-phase extraction coupled with high-performance liquid chromatography[J]. Food Analytical Methods, 2015, 8(8) : 2044-2051.
  • 6OUYANG H, WANG L, YANG S, et al. Chemilumines- cence reaction kinetics-resolved multianalyte immunoassay strategy using a bispecific monoclonal antibody as the unique recognition reagent[J]. Analytical Chemistry, 2015, 87(5) : 2952-2958.
  • 7XUE R, KANG T F, LU L P, et al. Electrochemical sensor based on the graphene-nafion matrix for sensitive determina- tion of organophosphorus pesticides[J]. Analytical Letters, 2013, 46(1):131-141.
  • 8黄柱进,刘雅琼,陈明明,高川,冯艳龙,董玉林,魏登贵,李曦.石墨烯修饰玻碳电极测定铅离子的研究[J].华中师范大学学报(自然科学版),2013,47(4):514-518. 被引量:6
  • 9SHI J, WANG Y, DU W, et al. Synthesis of graphene en- capsulated FeaC in carbon nanotubes from biomass and its ca- talysis application[J]. Carbon, 2015, 99: 330-337.
  • 10范跃娟,沙翠翠,唐旻奕,李梅,王洋,程寒.氧化石墨烯修饰碳纤维微电极电化学性能研究[J].华中师范大学学报(自然科学版),2015,49(6):901-906. 被引量:2

二级参考文献32

  • 1Xiao Zhenghui, Zhang Rui, Chen Xiangying, et al. Magneti- cally recoverable Ni @ carbon nanocomposites= Solid-state synthesis and the application as excellent adsorbents for heavy metal ions[J]. Applied Surface Science, 2012, 263: 795-803.
  • 2Rubio R, Huguet J, Rauret G. Comparative study of the Cd Cu and Pb determination by AAS and by ICP-AES in river water: Application to a mediterranean river (Congost river, Catalonia, Spain) [J]. Water Research, 1984, 18 (4); 423 -428.2.
  • 3Narin 1, Soylak M, Eli L, et al. Determination of trace metal ions by AAS in natural water samples after preconcen- tration of pyrocatechol violet complexes on an activated car- bon column[J]. Talanta, 2000, 52(6); 1041 -1046.
  • 4Wen Xiaodong, Deng Qingwen, Guo Jie, et al. Ultra-sensi- tive determination of cadmium in rice and water by UV-vis spectrophotometry after single drop mieroextraction [J ]. Spectrochimiea Acta Part A: Molecular and Biomolecular Spectroscopy, 2011, 79(3) :508-512.
  • 5Shaw M, Haddad P R. The determination of trace metal pol- lutants in environmental matrices using ion chromatography [J]. Environment International, 2004, 30(3) :403-431.
  • 6Chailapakul O, Korsrisakul S, Weena Siangproh, et al. Fast and simultaneous detection of heavy metals using a simple and reliable microchip-electrochemistry route: An alternative approach to food analysis[J]. Talanta, 2008, 74(4): 683-689.
  • 7Aragay G, Merkoci A. Nanomaterials application in electro- chemical detection of heavy metals[J]. Electrochimica Acta, 2012, 84: 49-61.
  • 8Liao Lei, Lin Yungchen, Bao Mingqiang, et al. High-speed graphene transistors with a self-aligned nanowire gate [J]. Nature, 2010, 467(7313) : 305-308.
  • 9Garaj S, Hubbard W, Reina A, et al. Graphene as a subnan ometre trans-electrode membrane [J]. Nature, 2010, 467 (7312) : 190-193.
  • 10Stankovieh S, Piner R D, Nguyen S T, et al. Synthesis and ext'oliation of isocyanate treated graphene oxide nanoplate- lets[J]. Carbon, 2006, 44(15): 3342-3347.

共引文献6

同被引文献5

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部