摘要 用Ag/Cu/SWNTs纳米复合材料修饰玻碳电极构筑了一种新的过氧化氢安培传感器.该纳米材料的形貌和成分用扫描电镜和能谱仪进行了表征,修饰电极的催化效果以循环伏安法(CV)进行了分析.在纳米铜的沉积电位为-0.3V,银溶液浓度为4mmol·L^(-1)下,该传感器检测过氧化氢时表现出宽的线性范围(1.33~170μmol·L^(-1)),低的检出限(0.86μmol·L^(-1),S/N=3),选择性、重现性能良好,电流响应快,能在2s内达到稳态电流,并可用于测定真实的消毒剂样品,获得满意的回收率. In this paper,a novel amperometric sensor is fabricated by surface modification of glassy carbon electrode with Ag/Cu/SWNTs nanocomposites to determine hydrogen peroxide(H2O2).The morphology and element composition of the material are investigated by scanning electron microscopy(SEM)and energy dispersive X-ray spectrum(EDS).The electrocatalysis properties are analyzed by cyclic voltammetry(CV).Under the optimized conditions(-0.3Vof electrodeposition voltage and 4mmol·L^-1 of silver nitrate concentration),the fabricated sensor displays a broader linear range and a lower detection limit for H2O2.The linear range is from 1.33 to 170μmol·L^-1 with a detection limit of 0.86μmol·L^-1(S/N=3).The sensor has good selectivity,reproducibility,long term stability with a swift response time of 2s and has been used to determine H2O2 in real disinfector samples with favorable recoveries.
出处 《西北师范大学学报(自然科学版)》 CAS 北大核心 2016年第4期52-56,126,共6页 Journal of Northwest Normal University(Natural Science)
基金 国家自然科学基金资助项目(21465004) 广西自治区自然科学基金资助项目(2012GXNSFAA053033) 广西民族师范学院校级项目(2012XYYB003) 广西高校桂西南特色植物资源化学重点实验室培育基地项目
关键词 电沉积 单壁碳纳米管 安培传感器 过氧化氢(H2O2) electrodeposition single-walled carbon nanotubes amperometric sensor hydrogen peroxide(H2O2)
  • 相关文献

参考文献23

  • 1WANG J, LIN Y, CHEN L. Organic-phase biosensors for monitoring phenol and hydrogen peroxide in pharmaceutical antibacterial products[J]. Analyst, 1993, 118: 277.
  • 2KULYS J, WANG L, MAKSIMOVIENE A. L-Lactate oxidase electrode based on methylene green and earbon paste[J]. Anal Chim Acta, 1993, 274:53.
  • 3何世伟,吴宏伟,习玲玲.离子液体掺杂聚苯胺/纳米铜修饰电极制备及其在过氧化氢测定中的应用[J].分析化学,2013,41(5):766-770. 被引量:6
  • 4王奕琛,姜秀娥.基于碳载小尺寸银纳米颗粒的过氧化氢电化学传感器[J].分析化学,2014,42(5):689-694. 被引量:8
  • 5LIJIMA S. Helical microtules of graphite carbon[J]. Nature, 1991, 354: 56.
  • 6DAI H, WONG E W, LIEBER C M. Probing electrical transport in nanomaterals conductivity of individual carbon nanotubes [J]. Science, 1996, 272 : 523.
  • 7HIURA H, EBBESEN T W, TANIGAKI K. Opening and purification of carbon nanotubes in high yields[J]. Advanced Materials , 1995, 7: 275.
  • 8BRITTO P J, SANTHANAM K S V, ALONSO V, et al. Improved charge transfer at carbon nanotube electrodes [ J ]. Advanced Materials, 1999, 11: 154.
  • 9HE J B, LIN X Q, PAN J. Multi-wall carbon nanotube paste electrode for adsorptive stripping determina-tion of quercetin.. A comparison with graphite paste electrode via voltammetry and chronopotentiometry[J]. Electroanal Chem , 2005, 17(18): 1681.
  • 10闫永臣,王宗花,毛蕾蕾,罗国安.L-酪氨酸功能化多壁碳纳米管的制备及表征[J].分析试验室,2006,25(8):17-20. 被引量:9

二级参考文献98

共引文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部