摘要
清溪水电站1号机组在2016年1月C级检修后,发现下导摆度超标,通过1号机各种记录进行分析,然后对下导摆度存在的问题进行了处理,使1号机的摆度恢复正常。
Qingxi Hydro Power Station No. one generator lower throw beyond the limitation after repair C level in January 2016, through analyzing various kinds of record about No. one generator, adjusted the guide tile to make No. one generator' s throw were within the normal range, this paper mainly introduced the problem' s reason and resolution procedures.
出处
《贵州电力技术》
2016年第6期13-14,6,共3页
Guizhou Electric Power Technology
关键词
下导摆度
超标
原因分析
处理
lower throw
beyond the limitation
reason analysis
resolution