摘要 Three-dimensional fluorescence excitation–emission matrix(EEM) coupled with parallel factor analysis(PARAFAC) was performed for a total of 18 water samples taken from three water sources(two lakes and one wastewater treatment plant(WWTP) secondary effluent),with the purpose of identifying the major ultrafiltration(UF) membrane foulants in different water sources. Three fluorescent components(C1, C2 and C3) were identified,which represented terrestrially derived humic-like substances(C1), microbially derived humic-like substances(C2), and protein-like substances(C3). The correlations between the different fluorescent components and UF membrane fouling were analyzed. It was shown that for the WWTP secondary effluent, all three components(C1, C2 and C3) made a considerable contribution to the irreversible and total fouling of the UF membrane.However, for the two lakes, only the C3 exhibited a strong correlation with membrane fouling, indicating that the protein-like substances were the major membrane foulants in the lake waters. Significant attachment of C1, C2 and C3 to the UF membrane was also confirmed by mass balance analyses for the WWTP secondary effluent; while the attachment of C1 and C2 was shown to be negligible for the two lakes. The results may provide basic formation for developing suitable fouling control strategies for sustainable UF processes. Three-dimensional fluorescence excitation–emission matrix(EEM) coupled with parallel factor analysis(PARAFAC) was performed for a total of 18 water samples taken from three water sources(two lakes and one wastewater treatment plant(WWTP) secondary effluent),with the purpose of identifying the major ultrafiltration(UF) membrane foulants in different water sources. Three fluorescent components(C1, C2 and C3) were identified,which represented terrestrially derived humic-like substances(C1), microbially derived humic-like substances(C2), and protein-like substances(C3). The correlations between the different fluorescent components and UF membrane fouling were analyzed. It was shown that for the WWTP secondary effluent, all three components(C1, C2 and C3) made a considerable contribution to the irreversible and total fouling of the UF membrane.However, for the two lakes, only the C3 exhibited a strong correlation with membrane fouling, indicating that the protein-like substances were the major membrane foulants in the lake waters. Significant attachment of C1, C2 and C3 to the UF membrane was also confirmed by mass balance analyses for the WWTP secondary effluent; while the attachment of C1 and C2 was shown to be negligible for the two lakes. The results may provide basic formation for developing suitable fouling control strategies for sustainable UF processes.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第7期215-223,共9页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China(No.51208140) the National Water Pollution Control and Treatment Science and Technology Major Project of China(No.2012ZX07201002)
关键词 Membrane fouling Organic substances Three-dimensional fluorescence matrix Parallel factor analysis Correlation analysis Membrane fouling Organic substances Three-dimensional fluorescence matrix Parallel factor analysis Correlation analysis
  • 相关文献

参考文献29

  • 1Ajmani, G.S., Goodwin, D., Marsh, K., Fairbrother, D.H., Schwab K.J., Jacangelo, J.G., et al., 2012. Modification of low pressuremembranes with carbon nanotube layers for fouling control. Water Res. 46, 5645-5654.
  • 2Chen, W., Westerhoff, P., Leenheer, J.A., Booksh, K., 2003. Fluorescence excitation-emission matrix regional integration to quantify spectra for dissolved organic matter. Environ. Sci. Technol. 37, 5701-5710.
  • 3Filloux, E., Gallard, H., Croue, J.P., 2012. Identification of effluent organic matter fractions responsible for low-pressure membrane fouling. Water Res. 46, 5531-5540.
  • 4Haberkamp, J, Ernst, M., Paar, H., Pallischeck, D., Amy, G., lekel, M., 2011. Impact of organic fractions identified by SEC and fluores- cence EEM on the hydraulic reversibility of ultrafiltration mem- brane fouling by secondary effluents. Desalin. Water Treat. 29, 73-86.
  • 5Her, N., Amy, G., Foss, D., Cho, J., Yoon, Y., Kosenka, P., 2002. Optimization of method for detecting and characterizing NOM by HPLC-size exclusion chromatography with UV and on-line DOC detection. Environ. Sci. Technol. 36, 1069-1076.
  • 6Howe, KJ., Clark, M.M., 2002. Fouling of microflltration and ultrafiltration membranes by natural waters. Environ. Sci. Technol. 36, 3571-3576.
  • 7Huang, W.W., Chu, H.Q., Dong, B.Z., Hu, M.L., Yu, Y., 2015. A membrane combined process to cope with algae blooms in water. Desalination 355, 99-109.
  • 8Ishii, S.K.L., Boyer, T.H., 2012. Behavior of reoccurring PARAFAC components in fluorescent dissolved organic matter in natural and engineered systems: a critical review. Environ. Sci. Technol. 46, 2006-2017.
  • 9Jermann, D., Pronk, W., Kagi, R., Halbeisen, M., Boller, M., 2008. Influence of interactions between NOM and particles on UF fouling mechanisms. Water Res. 42, 3870-3878.
  • 10Ke, X., Hongqiang, R., Lib, D., Jinju, G., Tingting, Z., 2013. A review of membrane fouling in municipal secondary effluent reclamation. Environ. Sci. Pollut. Res. Int. 20, 771-777.

同被引文献34

引证文献5

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部