建立了以固相萃取为前处理方式的气相色谱-质谱联用法(GC-MS)测定植物油中的胆固醇和4种植物甾醇的方法。样品经正己烷溶解,采用Florisil固相萃取柱,以氢氧化四甲基铵为洗脱液进行净化处理,后经HP-5 MS色谱柱(30 m×0.25 mm×0.25μm)分离,GC-MS选择离子扫描(SIM)模式检测,以保留时间和特征离子定性、定量。结果表明:5种甾醇在相应的质量浓度范围内线性关系良好,相关系数均大于0.999,方法检出限为0.2 mg/kg;在空白油样中进行3个水平的添加实验,样品的回收率为84.5%~105.0%,相对标准偏差为1.6%~4.4%。该方法前处理简单、无需皂化、回收率高、精密度好,适用于快速测定植物油样品中的5种甾醇。
A method for determining cholesterol and four phytosterols in vegetable oil was established by GC -MS with solid phase extraction as pretreatment method. The sample was dissolved in n -hexane, and purified by a Florisil solid phase extraction column with tetramethylammonium hydroxide as eluent, then separated on HP- 5 MS capillary chromatographic column (30 m ~ O. 25 mm ~ 0.25 I^m) , and qualitatively and quantitatively analyzed by GC - MS with retention time and characteristic ions under se- lected ion monitoring (SIM) mode. The results indicated that there were good linear relationships in cor- responding mass concentration ranges of the five sterols, the correlation coefficients were all higher than 0. 999, and the detection limit of the method was 0.2 mg/kg. The recoveries and relative standard devia- tions of five sterols were 84.5% - 105.0% and 1.6% -4.4% respectively in three levels addition ex- periment in blank oil. The method had the items of simpleness without saponification, high recovery and precision, suitable for rapid determination of five sterols in vegetable oil.
出处
《中国油脂》
CAS
CSCD
北大核心
2016年第7期94-98,共5页
China Oils and Fats