摘要 以某款空调外机配管为对象,结合理论模态计算方法和试验模态分析方法对配管进行动态特性研究。首先对空调外机配管结构建立动力学模型并用有限元分析软件对其进行理论模态计算,得出前12阶固有频率和振型。随后利用单点激励单点响应的方式对配管进行了试验模态分析,得到了系统在实际约束下前12阶的模态参数。研究表明:试验模态分析结果和有限元分析吻合,验证了理论模态的正确性,为进一步研究提供了可信的条件。同时,找出了配管额定工作时振动过大的原因,为减振措施和结构改进提供了可靠的依据。 The pipes connecting compressor and heat exchange coils plays an important role in the noise and vibration performance of air conditioner. In this paper,the dynamic characteristics of the pipes are analyzed with both FEM( finite element method) and experimental method. The first twelve natural frequencies and mode shapes were obtained from dynamic analysis of FEM model. Then,the experimental modal analysis was performed on the real pipes with hammer excitation method. The differences between the FEM analysis and experimental results were compared,and solutions to suppress pipe vibration has been proposed. The study shows that pipe vibration dynamic characteristics,which can be efficiently verified by experimental modal analysis,provides reliable theoretical basis for controlling vibration and noise of air-conditioner pipes.
出处 《机械科学与技术》 CSCD 北大核心 2016年第8期1195-1200,共6页 Mechanical Science and Technology for Aerospace Engineering
基金 国家自然科学基金地区基金项目(51465022 51264018)资助
关键词 空调 管道振动 模态分析 动态特性 air conditioner pipe vibration modal analysis dynamic characteristics
  • 相关文献

参考文献15

  • 1Ashley H, Haviland G. Bending vibrations of a pipe line containing flowing fluid [ J ]. Journal of Applied Mechanics, 1950,17:229-232.
  • 2Paidoussis M P. Flow-induced instabilities of cylindrical structures [ J ]. Applied Mechanics Reviews, 1987,40 (2) :163-175.
  • 3Paidoussis M P, Li G X. Pipes conveying fluid a model dynamical problem[ J ]. Journal of Fluid and Structures, 1993,7(2) : 137-204.
  • 4Paidoussis M P. Fluid-structure interactions: Vol 1: slender structures and axial flow [ M ]. San Diego, CA : Academic Press Inc, 1998.
  • 5Hairahayashi, Kazuhiro S. Measurement of vibration energy-flow in piping system of air-conditioner [ R ]. Technical Review-Mitsubishi Heavy Industries, 1988.
  • 6Okutsu N. Study on the vibration and stress of copper tubes in refrigerators and air conditioners, Nippon Kikai Gakkai Ronbunshu [ J ]. C Hen Transactions of the Japan Society of Mechanical Engineers, Part C, 1997, 63 ( 611 ) :2201-2205.
  • 7薛玮飞,张智,陈进,李贤华,杨九铭.空调配管模态仿真分析与实验研究[J].机械科学与技术,2010,29(6):822-825. 被引量:13
  • 8薛玮飞,张智,陈进,杨九铭,刘晓明.空调配管空间结构的动态仿真与优化[J].机械强度,2011,33(2):170-174. 被引量:15
  • 9苟兵旺,刘永寿,何洁,岳珠峰.输流管道在支承激励下的动态特性分析[J].机械科学与技术,2011,30(4):556-559. 被引量:4
  • 10周云,易伟建.用Poly MAX方法进行弹性地基板的实验模态分析[J].振动与冲击,2007,26(7):139-144. 被引量:28

二级参考文献55

共引文献109

同被引文献28

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部