不同扫描条件对单源双能CT水-碘浓度值稳定性的影响 被引量:1

The Influence on the Stability of Water-iodine Concentration in Different Single-Source Dual-Energy CT Scanning Conditions
下载PDF
导出
摘要 目的:研究单源双能CT的不同扫描条件对水浓度值稳定性的影响。方法:使用单源双能CT(GE Discovery HD750)选取不同的扫描参数进行有序组合对标准水模进行扫描,扫描参数包括:管电流:260、275、360、375、550、600、630、640m A;转速:0.5、0.6、0.7、0.8、0.9、1.0 s/r;扫描野:腹部large和medium;重建层厚/间距:5mm、5mm、1.25mm、1.25mm;螺距:1.375mm和0.984mm。共扫描552组数据,利用GSI general MD analysis软件后处理生成水-碘图像,测量每个序列的中间层面图像中心区水浓度值(ROI=600±30mm2)。采用Matlab 7.11.0软件中的stepwise函数对测量所得数据进行分析以获得5个不同扫描参数对水-碘浓度值影响的大小。结果:转速、电流、扫描野、螺距4个因素对水-碘浓度值的变化有显著影响(P<0.05),重建层厚对水-碘浓度值的影响无统计学意义(P=0.353)。结论:不同扫描条件对单源双能CT的水-碘浓度值有影响,其中转速、电流、扫描野、螺距对水碘浓度值的影响较为显著,重建层厚对水-碘浓度值无明显影响。 Purpose:To investigate the influence on the stability of water-iodine concentration in different single-source dual-energy CT scanning conditions. Methods:A GE standard water model was scanned by different scanning parameters of single-source dual-energy CT. Five hundred and twenty-two groups of data was acquired by scanning parameters orderly combined below: tube current: 260,275,360,375,550,600,630,640 m A); speed: 0.5,0.6,0.7,0.8,0.9,1.0s/rot); FOV: large and medium; thickness: 5mm,1.25mm; pitch: 1.375 mm,0.984 mm. The central water concentration of each sequence on iodine-water images,which were reconstructed by GSI general MD analysis software(ROI=600±30mm^2),was recorded. Influence of different scan parameters on the water concentrationwas analyzed with stepwise model on Matlab 7.11.Result:Speed,tube current,FOV and pitch were all with significant influence on water-iodine concentration,but thickness was with no significant influence(P =0.3530.05). Conclusion:Different scanning parameters of single-source dual-energy CT have influence on water-iodine concentration,especially the parameters of speed,tube current,FOV and pitch.
出处 《中国医学计算机成像杂志》 CSCD 北大核心 2016年第3期274-277,共4页 Chinese Computed Medical Imaging
基金 国家自然科学基金No.81470078~~
关键词 单源双能CT 扫描条件 水-碘浓度值 Single source-dual energy CT Scanning conditions Water-iodine concentration
  • 相关文献

参考文献15

  • 1Agrawal MD,Pinho DF,Kulkarni NM,et al. Oncologic Applications of Dual Energy CT in the Abdomen.RadioGraphics,2014,34:589-612.
  • 2Anderson NG,Butler AP.Clinical applications of spectral molecular imaging: potential and challenges. Contrast Media Mol. Imaging,2014,9:3 - 12.
  • 3Alessio AM, MacDonald LR.Quantitative material characterization from multi-energy photon counting CT. Med Phys, 2013,40:031108.
  • 4王明亮,林晓珠,缪飞,陈克敏,郑向鹏,滑炎卿,李剑颖,高娜,沈云.CT能谱成像对物质内碘含量测定的价值:体模研究[J].中国医学计算机成像杂志,2011,17(2):172-175. 被引量:41
  • 5Lv P, Lin XZ,Li J,et al. Differentiation of Small Hepatic Hemangioma from Small Hepatocellular Carcinoma: Recently Introduced Spectral CT Method.Radiology,2011,259: 720.
  • 6Liu X,Ouyang D,Li H,et al. Papillary Thyroid Cancer: Dual- Energy Spectral CT Quantitative Parameters for Preoperative Diagnosis of Metastasis to the Cervical Lymph Nodes. Radiology,2015,275:167-176.
  • 7Li A,Liang H, Li W, et al. Spectral CT Imaging of laryngeal and hypopharyngeal squamous cell carcinoma: evaluation of image quality and status of lymph nodes. PLoS One. 2013,8:e83492.
  • 8Morgan DE,Weber AC,Loekhart ME,et al. Differentiation of high lipid content from low lipid content adrenal lesions using single- source rapid kilovolt(peak)-switching dual-energy multideteetor CT. J Comput Assist Tomogr,2013,37:937-943.
  • 9郭仕涛,周实,黄钟杰,马兴灿,林珏慧,林顺发.能谱CT体外鉴别渗出性与漏出性浆膜腔积液的价值[J].中国CT和MRI杂志,2014,12(6):109-111. 被引量:14
  • 10孙平,吴祥才.多层CT螺距对重组图像空间分辨率的影响[J].中国医学工程,2015,23(8):18-19. 被引量:2

二级参考文献71

  • 1顾燕娣,陈元炯,王正磊.螺旋CT实际层厚的影响因素与CT图像质量的关系[J].上海医学影像,2003,12(3):165-167. 被引量:5
  • 2高德春,吴苔,毛定立,翁志高.改变扫描野对儿童体部CT图像质量的影响[J].中华放射学杂志,2005,39(4):402-405. 被引量:1
  • 3赖爱平,龚方戚,章士正.儿童CT检查射线剂量优化原则[J].中国儿童保健杂志,2005,13(4):342-343. 被引量:24
  • 4兰永树,黄文龙,朱德强,唐光才.影响CT值测量的因素及对策的探讨[J].实用放射学杂志,2006,22(3):352-355. 被引量:27
  • 5陈远清.医学影像技术与检查诊断及质量控制实用手册[M].长春:吉林电子出版社,2004.1246.
  • 6谢强,Hsich J.计算机断层成像技术:原理、设计、伪像和进展[M].北京:科学出版社,2006.192-228.
  • 7Donnelly L F,Emery K H,Brody A S,et al.Minimizing radiation dose for pediatric body applications of single-detector helical CT:strategies at a large children's hospital[J].AJR,2001,176(2):303-306.
  • 8Funama Y,Awai K, Nakayama Y,et al. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology,2005,237:905-910.
  • 9Kalra MK, Maher MM, Kamath RS,et al. Sixteen-detector row CT of abdomen and pelvis: a study for optimization of Z-axis modulation technique perfm'med in 153 patients. Radiology ,2004, 233:241-249.
  • 10Siegel MJ, Schmidt B, Bradley D, et al. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology,2004,233:515-522.

共引文献100

同被引文献8

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部