摘要 加速器质谱法是^(129)I最灵敏的检测方法。传统方法分析样品时通常需要复杂的化学制样流程,对样品中碘元素进行分离、富集和纯化,测试周期较长,成本高。在核应急分析等类型的应用研究中,需要对大批量样品中的^(129)I含量开展快速检测,针对此类应用需求特点,本研究尝试开发一种快速、流程简便并且成本低廉的^(129)I-AMS检测方法。以三种已知^(129)I水平的国际标准物质作为研究样品,将干燥和研磨均匀化的样品粉末直接与加入过本底碘的电热导体介质(Nb粉末)混合后压入靶座,实现快速制靶,进行加速器质谱测量,再结合制靶时称量的相关质量关系数据就能直接计算得出原始样品中的^(129)I活度。通过对测量数据与已知值进行比较分析验证了方法的可靠性,估算方法的探测下限可达0.15μBq?g^(-1)。 Background,aim,and scope Iodine-129 is one of the hard-to-measure radionuclides with a half-life T_(1/2)=15.7×10~6 years,and Accelerator Mass Spectrometry(AMS) is the most sensitive method for measuring ^(129)I.The primary source of ^(129)I in the earth have been altered in a significant way by human nuclear actions,and the ^(129)I now is an important indicator of the civil and military nuclear activities and nuclear accidents.A drawback of the AMS technique for measuring the ^(129)I is the time-consuming chemical separation required to prepare AMS targets from raw samples.This step significantly limits applications requiring rapid analyses and large numbers of samples,for example in monitoring studies associated with nuclear accidents.This work aims to develop a rapid AMS method for rapid determination of ^(129)I in environmental samples,especially for the emergency analysis.Materials and methods The only used chemicals is Niobium powder,blank iodine(Woodward iodine,WWI,contains no ^(129)I) and the ^(129)I standards.Three certified reference materials including sediment(IAEA-410),seaweeds(IAEA-446 and NIST-4359)were tested by this rapid method to verify the method.This work was implemented by eliminate the step of chemical separation of iodine from the raw sample materials,the samples were directly packed into target holder after dried and homogenized mixed with Nb powder,and the prepared target is directly used for AMS analysis.All targets are measured on Xi'an 3.0 MV AMS following the same steps as for the measurement of micro-iodine targets method,as described in(Liu,2015).In this approach,blank iodine(only ^(127)I) is added to a matrix of niobium(Nb) powder and mixed with dried raw sample,to improve the measurement of a stable ^(129)I/^(127)I ratio.Results The ion source behaved no abnormity on the targets with untreated raw samples materials,except very low stable iodine current output.The comparisons of the spectrometry from the blank targets,standard targets and sample targets showed a good resolution of ^(129)I,and the complex component in the targets has no bad effects on the ^(129)I spectrometry.The ^(129)I/^(127)I ratio measured by this rapid method were found to be in agreement with known values that used a conventional AMS method for the same material,after the subtraction of the background signal.The addition of blank iodine into the targets improved the stable iodine current greatly,but it diluted the ^(129)I level of the sample,which leads to the measured ^(129)I/^(127)I ratio does not reflect the real ^(129)I level,but if corrected by the dilution efficient,the^(129)I/^(127)I ratio were also found to be consistent with the well-known values within the errors.Noticed that in the case the dilution approach,the ^(127)I signal mostly contributed by the blank iodine added in the Nb powder,we can neglect the iodine content in the raw sample material and directly calculate the ^(129)I activity from the^(129)I/^(127)I ratio and the mass of the raw sample,the amount of Nb,and the iodine added to the Nb.The results are consistent with the established values,within errors.Discussion This rapid method were evaluated according to:signal stability and measurement reproducibility.A stable but increased intensity of the ^(127)I^(5+)current with iodine concentration was observed for the suite of reference samples,and multiple targets of the same reference material produced consistent ^(127)I and ^(129)I results.Therefore these criteria are satisfied.Conclusions This work developed a rapid and direct method for sensitive measurement of ^(129)I by AMS in^(129)I-rich environmental samples without wet-chemistry separation of iodine,and it was shown that such a direct AMS measurement method worked reasonably well for the two types of sample materials tested.All the ^(129)I/^(127)I ratios and ^(129)I activities measured by this method were found to be consistent with the known values within errors.And the time consumption of a batch with 40 unknown samples was shorten to 5 hours,compared to the conventional AMS method.And the detection limit of ^(129)I of this method was estimated to be 0.15 μBq·g^(-1).The final conclusion can be drawn that,it is practicable to directly measure ^(129)I/^(127)I ratios and ^(129)I activities using AMS without wet-chemistry separation in suitable cases.Recommendations and perspectives Since the seaweeds and sediment were tested as typical materials,it is expected that such a rapid measurement method can be also applied to other environmental solid materials,so long the ion source can function stably.This would be especially useful for the purpose of screening large numbers of samples to determine which ones should be subjected to more time-consuming but precise chemical processing.
出处 《地球环境学报》 2016年第3期314-322,共9页 Journal of Earth Environment
基金 国家自然科学基金项目(11405176)~~
关键词 碘-129(129I) 加速器质谱 快速检测 Iodine-129(129I) Accelerator Mass Spectrometry Rapid and direct measurement
  • 相关文献

参考文献4

二级参考文献36

  • 1周卫健,卢雪峰,武振坤,赵稳年,黄春海,李琳琅,程鹏.西安加速器质谱中心多核素分析的加速器质谱仪[J].核技术,2007,30(8):702-708. 被引量:12
  • 2Wagner M J M, Dittrich-Hannen B, Synal H-A, Suter M, Schotterer U. Nucl. Instr. Meth. B, 1996, 113: 490-494
  • 3Schmidt A, Schnabel Ch, Handl J, Jakob D, Michel R, Synal H-A, Lopez J M, Suter M. Sci. Total Environ., 1998, 223: 131-156
  • 4Straume T, Marchetti A A, Anspaugh L R. Health Phys., 1996, 71: 733-740
  • 5Fabryka-Martin J, Bentley, Elmore D and Airey P L. Geochim. Cosmochim. Acta, 1985, 49: 337~347
  • 6Yiou F, Raisbeck G M, Zhou Z Q and Kilius L R. Nucl. Instr. Meth. B, 1994, 92: 436-439
  • 7Edmonds H N, Smith J N, Livingston H D, Kilius L R, Edmond J M. Deep-Sea Res. I, 1998, 45: 1111-1125
  • 8ZhangCaihong(张彩虹) SongHailong(宋海龙) RenXiaona(任晓娜).J. Nucl. Radiochem. (核化学与放射化学),2002,24:210-213.
  • 9JiangSongsheng(蒋崧生) JiangShan(姜山) GuoHong(郭宏) YangBingfan(杨丙凡) ZhangCanzhe(张灿哲) ChenZha.Atom. Energy Sci. Technol. (原子能科学技术),1994,28:104-108.
  • 10JiangSongsheng(蒋崧生) HeMing(何明) XieYunmian(谢运棉) JiangShan(姜山) WuShaoyong(武绍勇).Nucl. Tech. (核技术)[Z].,2000,23.43-46.

共引文献17

同被引文献8

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部