分光光度法测定水中亚硝酸盐含量的不确定度评定 被引量:13

Evaluation on Uncertainty Measurement of Measuring the Nitrite Content in Water by Spectrophotometer
下载PDF
导出
摘要 评定分光光度法测定水中亚硝酸盐含量的不确定度。采用紫外分光光度法测定水中亚硝酸盐的含量,运用测量不确定度的基本方法和程序,分析影响结果不确定度的各种因素,建立数学模型,合成计算亚硝酸盐含量的不确定度。通过分析计算标准溶液的纯度、标准储备液配置、标准溶液稀释过程、曲线拟合过程、待测样品稀释、样品测定重复性等带来的不确定度分量,最后合成水中亚硝酸盐的含量的不确定度为0.485 mg/L,测量扩展不确定度:0.017 mg/L(K=2)。 Spectrophotometry was used to determine the uncertainty of nitrite contents in water. Ultraviolet spectrophotometry was adopted to determine the nitrite contents in water. Basic method and procedure measuring uncertainty were also used to analyze various factors influencing the results. Mathematical model was established to calculate the uncertainty of nitrite contents. By analyzing and calculating the uncertainty components generated by purity of standard solution, standard stock solution allocation, dilution process of standard solution, curve fitting process, dilution of unknown samples and sample measurement repeatability, it was found that the uncertainty of nitrite contents in water was 0.485 mg/L and the uncertainty in measurement reached 0.017 mg/L(K=2).
出处 《食品研究与开发》 CAS 北大核心 2016年第9期174-177,共4页 Food Research and Development
关键词 分光光度法 亚硝酸盐 不确定度评定 spectrophotometry nitrite uncertainty evaluation
  • 相关文献

参考文献6

  • 1中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2002..
  • 2张成悌.测量不确定度评定中的若干问题[J].中国测试技术,2007,33(5):24-28. 被引量:43
  • 3国家质量监督检验检疫总局.JJF 1059.1-2012测量不确定度评定与表示[S].北京:中国标准出版社,2013.
  • 4中国实验室国家认可委员会.ISO/IEC 17025:2005检测和校准实验室认可准则[S].北京:国家质量监督检验检疫总局,2005.
  • 5中华人民共和国卫生部,中国国家标准化管理委员会.GB/T5750.5-2006生活饮用水标准检验方法无机非金属指标[S].北京:中国标准出版社,2007.
  • 6国家质量监督检验检疫总局.JJG196-2006常用玻璃量器检定规程[S].北京:中国计量出版社,2006:6-9.

二级参考文献2

  • 1Kurt Rantseh(韧席),李慎安,译.测量与量仪的准确度[M].北京:机械工业出版社,1958.
  • 2国家质量监督检验检疫总局.JJG146-2003,量块[S].北京:中国计量出版社,2004.