摘要 建立了超高效液相色谱-串联三重四级杆质谱(UPLC-MS/MS)检测生鲜肉中四环素类抗生素残留的分析方法。方法采用C18色谱柱(50 mm×2.1 mm,1.7μm)分离,柱温30℃,样品室温度10℃。流动相由A相(乙腈)和B相(0.1%甲酸溶液)组成,流速为0.4 m L/min,采用梯度洗脱。在ESI正离子模式下,采用多反应离子监测模式进行测定,可以在5 min内完成检测。四种四环素类抗生素土霉素、金霉素、四环素和强力霉素均在10~200μg/m L范围内有良好的线性关系,相关系数大于0.995。样品最低检出限为50μg/kg,回收率在80%~89%之间,相对标准偏差为2.5%~6.3%。该方法准确度高,灵敏度好,适用于生鲜肉中四环素类抗生素的检测。 An ultra performance liquid chromatography -electrospray ionization tandem mass spectrometry ( UPLC-ESI-MS/MS) method for the determination of Antibiotics Residues in fresh meat was developed .Methods C18 chromatographic column (50mm ×2.1mm, 1.7 μm), the solvent system was composed of mobile phase A (Acetonitrile), and mobile phase B (water with 0.1%methanoic acid ).The flow rate was 0.4 mL/min and gradient elution, and the temperature is held constant at 30℃within a thermostated column .Multiple reaction monitoring ( MRM) in ESI positive mode was used for quantitation .The Antibiotics Residues was successfully detected within 5 min.Antibiotics Residues have good linear relationship in the range of 0.5μg /L -8μg /L with the correlation coefficient larger than 0.995.The detection limit was 50 μg /kg, and the recovery is between 80%-89% with the relative standard deviation between 2.5%~6.3%.An accurate and sensitivity method was developed in this study .The established method has been successfully applied to the determination of antibiotics residues in fresh meat .
作者 赵飞 高广慧
出处 《山东化工》 CAS 2016年第14期48-50,共3页 Shandong Chemical Industry
关键词 超高效液相色谱-串联三重四级杆质谱 四环素类抗生素 生鲜肉 UPLC -MS/MS antibiotics residues fresh meat
  • 相关文献

参考文献5

二级参考文献83

共引文献73

同被引文献51

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部