摘要 当前常见的数据中心冷却方式不仅耗能大,而且安全隐患大,已难以满足数据中心发展要求,数据中心冷却方案的节能研究已变得非常重要且迫在眉睫。本文阐述的一种新型数据中心冷却方案不仅能够很好地解决数据中心的冷却问题,而且安全性高,节能效果好。通过验证,该方案能够在实际应用中切实取得良好的经济效益和社会效益。 The current data center(IDC)cooling mode is not only energy consuming,but also with great potential safety hazard.All above makes it difficult to meet the development requirements of IDC,and energy-saving research of IDC cooling scheme becomes very important and urgent.The new type of IDC cooling scheme mentioned in this paper can well solve the cooling issue of the data center with high safety performance and energy-saving effect.Through verification,the scheme can achieve good economic and social benefits in the practical application.
作者 肖皓斌
出处 《制冷与空调》 2016年第7期26-30,共5页 Refrigeration and Air-Conditioning
关键词 数据中心 冷却方案 节能 data center cooling scheme energy-saving
  • 相关文献

参考文献3

二级参考文献7

  • 1赛迪顾问股份有限公司.2009-2010年中国数据中心IT应用市场研究年度报告[R].北京,2010.
  • 2赛迪顾问股份有限公司.2009-2010年中国X86服务器市场研究年度报告[R].北京,2010.
  • 3赛迪顾问股份有限公司.2009-2010年中国Non-X86服务器市场研究年度报告[R].北京,2010.
  • 4洪钊峰,大公.2008-2009年服务器新技术应用状况调查[EB/OL].http://server.it168.com/a2009/0116/2631000000263296-1.shtml,2009-01-19.
  • 5U.S.Environmental Protection Agency.Report to Congress on Server and Data Center Energy Efficiency-public law 109-431[R].Washington,2007.
  • 6Koomey,J.G..Estimating total power consumption by servers in the U.S.and the world[EB/OL].http://enterprise.amd,com/Downloads/svrpwrusecompletefinal.pdf,2007-02-15.
  • 7谷立静,周伏秋,孟辉.我国数据中心能耗及能效水平研究[J].中国能源,2010,32(11):42-45. 被引量:111

共引文献116

同被引文献18

引证文献2

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部