Design and optimization of resistive anode for a two-dimensional imaging GEM detector

Design and optimization of resistive anode for a two-dimensional imaging GEM detector
原文传递
导出
摘要 A resistive anode for two-dimensional imaging detectors, which consists of a series of high resistivity pads surrounded by low resistivity strips, can provide good spatial resolution while reducing the number of electronics channels required. The optimization of this kind of anode has been studied by both numerical simulations and experimental tests. It is found that to obtain good detector performance, the resistance ratio of the pads to the strips should be larger than 5, the nonuniformity of the pad surface resistivity should be less than 20%, a smaller pad width leads to a smaller spatial resolution, and when the pad width is 6 mm, the spatial resolution (a) can reach about 105 μm. Based on the study results, a 2-D GEM detector prototype with optimized resistive anode is constructed and a good imaging performance is achieved. A resistive anode for two-dimensional imaging detectors, which consists of a series of high resistivity pads surrounded by low resistivity strips, can provide good spatial resolution while reducing the number of electronics channels required. The optimization of this kind of anode has been studied by both numerical simulations and experimental tests. It is found that to obtain good detector performance, the resistance ratio of the pads to the strips should be larger than 5, the nonuniformity of the pad surface resistivity should be less than 20%, a smaller pad width leads to a smaller spatial resolution, and when the pad width is 6 mm, the spatial resolution (a) can reach about 105 μm. Based on the study results, a 2-D GEM detector prototype with optimized resistive anode is constructed and a good imaging performance is achieved.
出处 《Chinese Physics C》 SCIE CAS CSCD 2016年第8期90-95,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(11375219) CAS Center for Excellence in Particle Physics(CCEPP)
关键词 resistive anode GEM two dimensional detector spatial resolution imaging distortion resistive anode, GEM, two dimensional detector, spatial resolution, imaging distortion
  • 相关文献

参考文献14

  • 1F. Sauli et al, Nucl. Instrum. Methods A, 8:386 (1997).
  • 2D. Abbaneo et al, JINST, 8:C12031 (2013).
  • 3F. Thibaud et al, JINST, 9:C02005 (2014).
  • 4A. Balla et al, Nucl. Instrum. Methods A, 628:194 198 (2011).
  • 5M. Lampton et al, Review of Scientific Instruments, 50(9): 1093:1097 (1979).
  • 6T. Doke et al, Nucl. Instrum. Methods A, 261:605-609 (1987).
  • 7A. Banu et al, Nucl. Instrum. Methods A, 593:399 (2008).
  • 8A. Sarvestani et al, Nucl. Instrum. Methods A, 419:444 (1998).
  • 9M. Y. Dong et al, Chin. Phys. C, 37(2): 026002 (2013).
  • 10H. Wagner et al, Nucl. Instrum. Methods A, 482: 334 346 (2002).

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部