期刊文献+

不锈钢四通阀应用研究 被引量:2

Study on the Application of Four-way Valve on Stainless Steel
下载PDF
导出
摘要 本文介绍了不锈钢四通阀在热泵空调上的应用研究,四通阀的阀体、阀座和端盖都是采用不锈钢材料制作,重量较轻成本低,热阻大,热损失较小,有利于空调器的节能。通过理论分析和实验验证后发现,不锈钢四通阀在热泵机型上可以提高空调制冷制热量,提高空调能效比。 In this paper, we adopted stainless steel four-way valve in air conditioner for application research, which body, seat and cover for four-way value are made of stainless steel. And its weight is light, thermal resistance is high- er, heat loss is less, that conducive to energy saving of air conditioner. In addition, stainless steel four-way valve is cheaper. In this paper, through theoretical analysis and experimental verification, it found that the application of stainless steel four-way valve in the air conditioner can improve refrigeration capacity, heat capacity and COP (coefficient of performance, W/W).
出处 《日用电器》 2015年第12期53-58,共6页 ELECTRICAL APPLIANCES
关键词 空调 传热 不锈钢四通阀 air conditioner heat transfer stainless steel four-way valv
  • 相关文献

参考文献4

二级参考文献24

  • 1张明圣.单元式空调机和冷水机组国家能效标准制定[J].制冷技术,2005,25(2):11-14. 被引量:2
  • 2Ding G L. Recent development in simulation techniques for vapour-compression refrigeration systems[J]. International Journal of Refrigeration, 2007, 30 (7): 1119-1133.
  • 3Murphy W W. Analysis of the performance improvements of central air conditioners for residences[D]. Purdue University, 1978.
  • 4Krishnan R R. Evaluating reversing valve performance in heat pump systems[J]. ASHRAE Transaction, 1986, 92 (2B) : 71-80.
  • 5Damasceno G D S, Lee W N T, Rooke S P. Performance of heat pump reversing valves and comparison through characterizing parameters[J]. ASHRAE Transaction, 1988, 94(1): 304-317.
  • 6Goldschmidt V M, Scharf R R R, White L. Measurement of refrigerant leakage in reversing valves[J]. ASHRAE Transaction, 1984, 90 (1) : 185 - 195.
  • 7Lee W N T, Damasceno G D S, Goldschmidt V M Heat transfer in heat pump reversing valve bodies [J] International Journal of Referigeration, 1988 (11) 159-163.
  • 8Young D J. Development of a northern climate residential air-source heat pump[J]. ASHREA Transaction, 1980, 86 (1) : 671-684.
  • 9Hargraves D P. A refrigerant enthalpy method for measuring reversing valve heat transfer[J]. ASHREA Transaction, 1986, 92 (2B) : 88-93.
  • 10Moffat R J. Describing the uncertainties in experimental results[J]. Experimental Fluid and Thermal Science, 1998(1): 3-17.

共引文献20

同被引文献5

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部