期刊文献+

正常颅脑能谱CT成像各单能量图像质量的分析研究 被引量:2

Spectral CT imaging of normal brain: a study on quality of optimal monochromatic image
下载PDF
导出
摘要 目的:研究能谱CT成像在显示正常颅脑结构时的最佳单能量图,从而提高图像质量。方法:对60例经宝石能谱CT扫描的患者图像进行回顾性分析,将所得原始图像在40、45、50、55、60、65、70、75、80、85、90、95、100、105、110、115、120、130、140 ke V下重建19组CT图像。选取半卵圆中心、基底节区、小脑最大层面,分别测量每一组图像各感兴趣区的CT值及噪声,以计算不同ke V下的对比噪声比(contrast to noise ratio,CNR)、信噪比(signal noise ratio,SNR)。结果:小脑皮质、髓质的最佳SNR均为70 ke V,最大CNR为40 ke V;半卵圆中心层面的皮质、髓质在70 ke V具有最佳SNR,在40 ke V具有最大CNR;在基底节区层面中,内囊在70 ke V具有最佳SNR,苍白球在65 ke V具有最佳SNR,该层面在50 ke V具有最大CNR。除小脑的最大CNR比70 ke V的CNR大(P=0.000)外,基底节区层面及半卵圆中心层面的最大CNR与70 ke V的CNR没有统计学差异(P分别为0.066、0.249)。结论:进行颅脑CT能谱成像时,70 ke V是最佳单能量水平,能够清晰地显示颅脑的结构。 Objective To study the quality of the optimal monochromatic image of normal brain by spectral CT. Methods Totally 60 cases were detected with spectral CT scanner, whose images were analyzed retrospectively, and 19 sets of monochromatic images were obtained from a single GSI acquisition: 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105,110, 115, 120, 130, 140 ke V respectively, in which sets the centrum ovale, basal ganglia region, cerebellum levels were selected and measured, including CT value, noise on each set of images, and the contrast to noise ratios and signal to noise ratios were calculated. Results The best signal to noise ratios of cerebellar cortex and medulla were 70 ke V, the maximum contrast to noise and signal of cerebel was 40 ke V; The best signal to noise ratios of centrum semiovale cortex and medulla were 70 ke V, the maximum contrast to noise and signal of centrum semiovale was 40 ke V; In the level of the basal ganglia capsule,the best signal to noise ratios of capsula interna and globus pallidus were 70 and 65 ke V respectively, the maximum contrast to noise and signal of centrum semiovale was 50 ke V. There was statistically significant difference between the value of the maximum contrast to noise and signal of the cerebel and that of 70 ke V(P =0.000), which had no statistically significant difference in centrum semiovale and basal ganglia capsule(P =0.066 and 0.249 respectively). Conclusion The optimal monochromatic energy level of normal brain is 70 ke V on spectral CT image, which can display anatomic structure of brain clearly.
机构地区 解放军
出处 《医疗卫生装备》 CAS 2016年第7期97-100,共4页 Chinese Medical Equipment Journal
关键词 能谱CT成像 颅脑 图像质量 单能量图 spectral CT imaging brain image quality monochromatic image
  • 相关文献

参考文献10

  • 1叶晓华,周诚,吴国庚,王妍焱,曹会志,沈云.CT能谱单能量成像对不同肝脏肿瘤检出影响的初步探讨[J].中华放射学杂志,2011,45(8):718-722. 被引量:69
  • 2王健.宝石CT的技术突破和临床应用[J].国际放射医学核医学杂志,2009,33(2):126-128. 被引量:29
  • 3GRASER A,JOHNSON T R,CHANDARANA H,et al.Dual energy CT:preliminary observationsand potential clinical applications in the abdomen[J].Eur Radiol,2009,19(1):13-23.
  • 4林晓珠,沈云,陈克敏.CT能谱成像的基本原理与临床应用研究进展[J].中华放射学杂志,2011,45(8):798-800. 被引量:297
  • 5LI H,HE D,LAO Q,et al.Clinical value of spectral CT in diagnosis of negative gallstones and common bile duct stones[J].Abdominal Imaging,2015,40(6):1 587-1 594.
  • 6HOU W S,WU H W,YIN Y,et al.Differentiation of lung cancers from inflammatory masses with dual-energy spectral CT imaging[J].Acad Radiol,2015,22(3):337-344.
  • 7LIU X,OUYANG D,LI H,et al.Papillary thyroid cancer:dual-energy spectral CT quantitative parameters for preoperative diagnosis of metastasis to the cervical lymph nodes[J].Radiology,2015,275(1):167-176.
  • 8LV P,ZHANG Y,LIU J,et al.Material decomposition images generated from spectral CT:detectability of urinary calculi and influencing factors[J].Acad Radiol,2014,21(1):79-85.
  • 9LV P J,LIN X Z,LI J Y,et al.Differentiation of small hepatic hemangioma from small hepatocellular carcinoma:recently introduced spectral CT method[J].Radiology,2011,259(3):720-729.
  • 10董海鹏,林晓珠,缪飞,张帅,沈云,陈克敏.颅脑CT能谱成像的最佳单能量选择研究[J].诊断学理论与实践,2011,10(6):531-534. 被引量:7

二级参考文献26

  • 1韩金生,宋晓敏.多层螺旋CT冠状动脉成像的临床应用[J].黑龙江医学,2004,28(7):525-526. 被引量:2
  • 2Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilovohage switching: improved image quality as compared with that obtained with conventional 120 kVp CT. Radiology, 2011 ,In press.
  • 3Lv P, Lin XZ, Li J, et al. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced soectral CT method. Radioloav. 2011. In nress.
  • 4Lin XZ, Miao F, Li JY, et al. High-definition CT gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction. J Comput Assist Tomogr, 2011, 35:294-297.
  • 5Zhao LQ, He W, Li JY, et al. Improving image quality in portal venography with spectral CT imaging. Eur J Radiol, 2011, In press.
  • 6Feuerlein S, Roessl E, Proksa R, et al. Muhienergy photoncounting K-edge imaging: potential for improved luminal depiction in vascular imaging. Radiology, 2008, 249 : 1010-1016.
  • 7Pan D, Roessl E, Schlomka JP,et al. Computed Tomography in color: nanok-enhanced spectral CT molecular imaging. Angew Chem Int Ed Engl,2010, 49:9635-9639.
  • 8Cormode DP, Roessl E, Thran A, et al. Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles. Radiology, 2010, 256:774-782.
  • 9Shikhalievl PM, Fritz SG. Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application. Phys Med Biol, 2011, 56: 1905-1930.
  • 10Anderson NG, Butler AP, Scott NJA, et al. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE. Eur Radiol, 2010,20:2126-2134.

共引文献373

同被引文献25

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部