白内障术前两种角膜散光标记方法的对比研究 被引量:4

Comparative study of two corneal astigmatism marker methods before cataract surgery
下载PDF
导出
摘要 目的评价在行白内障超声乳化吸出联合Toric人工晶状体植入术前,2种常用的角膜散光标记方法的准确性。方法本研究为前瞻性随机对照研究。60例(60眼)患者被随机分为2组,每组各30例,分别按2种不同方法进行术前角膜散光标记。一种方法是裂隙灯显微镜下1 m L注射器针头标记法,另一种为toric专用标记器标记法,标记后裂隙下用数码照相机在后反射光下拍摄眼前节数字图像,记录标记,并用Photoshop软件对数字图像进行分析,对2组旋转偏差和垂直偏差进行评估。结果裂隙灯标记组旋转偏差较小,为(3.2±1.9)°;标记器组旋转偏差为(5.9±4.1)°,2组差异有统计学意义(P<0.01)。裂隙灯标记组垂直偏差也较小,为(0.27±0.18)mm,标记器组垂直偏差为(0.57±0.31)mm,2组差异也有统计学意义(P<0.01)。结论裂隙灯标记法旋转偏差和垂直偏差均小于toric标记器法,因此建议尽量采用裂隙灯标记法来标记患者的水平子午线,可保证散光轴线定位的精确性。 Objective To compare the accuracy of two corneal astigmatism marker methods before phacoemulsification and Toric intraocular lens implantation. Methods This study was a prospective randomized controlled study. 60 patients were randomly divided into tw o groups,30 cases in each group,and tw o corneal astigmatism marker methods were used. The first methods were marked with an 1 m L syringe needle under the slit lamp,and the second device with Toric marker used specially for marking corneal astigmatism. The corneal astigmatic axis was marked and then a digital camera was used to capture the anterior segment of digital image in the post reflective light. The marker was documented and the digital images were analyzed by photoshop softw are,and the rotational deviation and vertical misalignment were also assessed. Results The least rotational misalignment was observed in the slit lamp group with the mean deviation( 3. 2 ±1. 9) °,which in the Toric marker group was( 5. 9 ± 4. 1) °,the difference betw een the tw o groups was statistically significant( P〈 0. 01). The least vertical misalignment was also observed in the slit lamp group with the mean deviation( 0. 27 ± 0. 18) mm,which in the Toric marker group was( 0. 57 ± 0. 31) mm,there was significant difference betw een tw o groups( P〈 0. 01). Conclusion The least vertical misalignment and rotational misalignment with slit lamp methods are all smaller than those with Toric marker,so suggest use slit lamp to mark the meridian,which can improve the accuracy of the astigmatism axis.
出处 《眼科新进展》 CAS 北大核心 2016年第8期748-750,共3页 Recent Advances in Ophthalmology
关键词 白内障 角膜散光 标记 对比研究 cataract corneal astigmatism marker comparative study
  • 相关文献

参考文献12

  • 1FERRER-BLASCO T,MONTES-MlO R,PEIXOTO-DE-MATOS SC, GONZALEZ-MEUOME JM, CERVINO A. Prevalence of corneal astigmatism before cataract surgery[J]. J Cataract Refract Surg,2009,35(1):70-75.
  • 2HOFFMANN PC,HUTZ WW. Analysis of biometry and preva- lence data for comeal astigmatism in 23 ,239 eyes[J]. J Cata- ract Refract 2010,36(9):1479-1485.
  • 3MUFTUOGLU O,PRASHER P, CHU C, MOOTHA W,VERITY SM, CAVANAGH HD. Laser in situ keratomileusis for residual refractive errors after apodized diffractive multifocal intraoc- ular lens implantation[J]. J Cataract Refract Surg,2009,35(6):1063-1071.
  • 4MUFTUOGLU O,DAO L,CAVANAGH HD,MCCULLEY JP, BOWMAN RW. Limbal relaxing incisions at the time of apo- dized diffractive multifocal intraocular lens implantation to reduce astigmatism with or without subsequent laser in situ keratomileusis[J]. J Cataract Refract 2010,36(3):456-464.
  • 5MENDICUTE J,IRIGOYEN C,RUIZ M,ILLARRAMENDI I, FERRER-BLASCO T,MONTES-MICO R. Toric intraocular lens versus opposite clear corneal incisions to correct astig- matism in eyes having cataract surgery[J]. J Cataract Re- fract Surg ,2009,35(3):451-458.
  • 6FEUPE A,ARTIGAS JM, DIEZ-AJENJO A, GARCIA-DOMENE C,ALCOCER P. Residual astigmatism produced by toric in- traocular lens rotation[J]. J Cataract Refract Surg,2011,37(10):1895-901.
  • 7CARVALHO MJ,SUZUKI SH,FREITAS LL,BRANCO BC, SCHOR P,LIMA AL. Limbal relaxing incisions to correct comeal astig- matism during phacoemulsification[J]. J Refract Surg ,2007,23(5):499-504.
  • 8WEINAND F,JUNG A,STEIN A,PFUTZNER A,BECKER R, PAVLOVIC S. Rotational stability of a single-piece hydropho- bic aciylic intraocular lens: new method for high-precision rotation control[J]. J Cataract Refract Surg,2007,33(5):800-803.
  • 9PATEL CK,ORMONDE S, ROSEN PH,Bron AJ. Postoperative intraocular lens rotation : a randomized comparison of plate and loop haptic implants[J]. Ophthalmology,1999,106(11):2190-2195.
  • 10NORRBY S. Sources of error in intraocular lens power cal- culation[J]. J Cataract Refract Surg,34(4):368-376.

同被引文献25

引证文献4

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部