期刊文献+

基于体素的颅面部锥形束CT三维重叠准确性及可靠性评估 被引量:7

Accuracy and reliability of three-dimensional craniofacial cone-beam CT superimposition method based on voxel registration
原文传递
导出
摘要 目的建立基于体素的颅面部锥形束CT三维重叠方法,评估不同基准区域重叠的准确性和可靠性。方法对一个完整干颅骨进行3次锥形束CT扫描,每次间隔2周;另对10名成年志愿者进行两次锥形束cT扫描,间隔1个月。使用Analyzel2.0软件,建立基于体素的锥形束cT三维重叠方法,并分别以双颧部和前颅底为基准区域进行重叠。重叠后使用GeomagicQualify2013软件对颅面部各区域进行面距测量,3位操作者重复3次。使用SPSS19.0软件分析重叠方法的准确性和可靠性。结果以双颧部为基准区域重叠时,干颅骨的面距均值为0.035~0.064mm,志愿者的面距均值为0.099—0.182mm;以前颅底为基准区域重叠时,干颅骨的面距均值为0.038—0.071mm,志愿者的面距均值为0.127—0.218mm;均显著小于锥形束CT体素尺寸0.25mm(P〈0.05)。3位操作者共9次操作的各面距测量值总体差异均无统计学意义(P〉0.05)。结论以颅面双颧部和前颅底为基准区域的基于体素的锥形束CT三维重叠方法有较高的准确性和可靠性,可用于颅面部治疗效果的三维评价。 Objective To set up a three-dimensional(3D) craniofacial cone-beam CT(CBCT) superimposition method based on voxel registration, and evaluate the accuracy and reliability of different reference superimposition areas. Methods CBCT scans were taken on a dry skull for three times with a time-interval of two weeks, and CBCT scans were taken on ten adult volunteers twice with a time-interval of one month. The 3D superimposition based on voxel registration was set up by means of Analyze 12.0. The bilateral-zygomatic bone and anterior cranial base were selected as different reference areas for voxel overlapping. The 3D overlapping images were output into Geomagie Qualify 2013, and the surface distances on different eraniofacial regions were measured. Three operators repeated three times of these superimposition and measurement. SPSS 19.0 were used to analyze the accuracy and reliability. Results When bilateral-zygomatic bone used as superimposition reference, the mean surface distance range of dry skull were from 0.035 to 0.064 mm, and volunteers from 0.099 to 0.182 mm. When the anterior cranial base used as superimposition reference, the mean surface distance range of dry skull were from 0.038 to 0.071 mm, and volunteers from 0.127 to 0.218 mm. All these mean values were less than the CBCT voxel size 0.25 mm(P〈0.05), and got sub-pixel precision. No significant difference was found between the different operators at different times(P〉0.05). Conclusions This study showed the high accuracy and reliability of 3D CBCT superimposition based on voxel registration, either the anterior cranial base or the bilateral-zygomatie bone as reference. This method could be used for evaluating 3D eraniofacial treatment effects.
出处 《中华口腔医学杂志》 CAS CSCD 北大核心 2016年第8期475-479,共5页 Chinese Journal of Stomatology
基金 北京市科学技术委员会首都临床特色应用研究基金(Z131107002213047)
关键词 锥束计算机体层摄影术 可重复性 结果 体素 配准 准确性 Cone-beam computed tomography Reproducibility of results Voxel registration Accuracy
  • 相关文献

参考文献12

  • 1Cevidanes LH, Bailey LJ, Tucker SF, et al. Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery[J]. Am J Orthod Dentofacial Orthop, 2007, 131(1): 44-50. DOI: 10. 1016/j.ajodo.2005.03.029.
  • 2张倩倩,于艳玲.CBCT应用于口腔正畸领域的研究进展[J].中华口腔正畸学杂志,2013,20(3):170-172. 被引量:4
  • 3Wells WM 3rd, Viola P, Atsumi H, et al. Multi-modal volume registration by maximization of mutual information[J]. Med Image Anal, 1996, 1(1): 35-51.
  • 4Park TJ, Lee SH, Lee KS. A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model[J]. Korean J Orthod, 2012, 42(4): 169-181. DOI: 10.4041/kjod.2012A2AA 69.
  • 5Lagrav~re MO, Major PW, Carey J. Sensitivity analysis for plane orientation in three-dimensional cephalometric analysis based on superimposition of serial cone beam computed tomography images[J]. Dentomaxillofac Radiol, 2010, 39(7): 400-408. DOI: 10.1259/dmfr/17319459.
  • 6Hwang JJ, Kim KD, Park H, et al. Factors influencing superimposition error of 3D cephalometric landmarks by plane orientation method using 4 reference points: 4 point superimposition error regression model[J]. PLoS One, 2014, 9(11): el 10665. DOI: 10.1371/journal.pone.0110665.
  • 7Almukhtar A, Ju X, Khambay B, et al. Comparison of the accuracy of voxel based registration and surface basedregistration for 3D assessment of surgical change following orthognathic surgery[J]. PLoS One, 2014, 9(4): e93402. DOI: 10.1371/journal.pone.0093402.
  • 8Nada RM, Maal TJ, Breuning KH, et al. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches[J]. PLoS One, 2011, 6(2): e16520. DOI: 10.1371/journal.pone.0016520.
  • 9Cevidanes LH, Heymann G, Comelis MA, et al. Superimposition of 3-dimensional cone-beam computed tomography models of growing patients[J]. Am J Orthod Dentofacial Orthop, 2009, 136(1): 94-99.
  • 10傅民魁.口腔正畸学[M],5版.北京:人民卫生出版社,2007:1.

二级参考文献27

  • 1陈贵云,张江.基于三维互信息的多模医学图像配准[J].时珍国医国药,2010,21(12):3321-3322. 被引量:1
  • 2冯林,管慧娟,滕弘飞.基于互信息的医学图像配准技术研究进展[J].生物医学工程学杂志,2005,22(5):1078-1081. 被引量:19
  • 3Walker L, Enciso R, Mah J. Three dimensional localization of maxillary canines with cone-beam computed tomography. Am J Orthod Dentofacial Orthop,2005,128(4) :418-423.
  • 4Kumar V, Ludlow J, Soares Cevidanes LH, et al. In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod, 2008,78 (5) :873-879.
  • 5Grauer D, Cevidanes LS, Styner MA, et al. Accuracy and landmark error calculation using cone-beam computed tornography-generated cephalograms. Angle Orthod, 2010,80 (2) :286-294.
  • 6Periago DR, Scarfe WC, Moshiri M, et al. Linear accuracy and reliability of cone beam CT derived 3 dimensional images constructed using an orthodontic volumetric rendering program. Angle Orthod,2008,78(3) :387-395.
  • 7Kim Y, Park JU, Kook YA. Alveolar bone loss around incisors in surgical skeletal Class III patients. Angle Orthod, 2009,79(4):676-682.
  • 8King KS, Lain EW, Faulkner MG,et a. Predictive factors of vertical bone depth in the paramedian palate of adolescents. Angle Orthod, 2006,76 (5) : 745-751.
  • 9Honey OB, Scarfe WC, Hilgers MJ, et al. Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography. Am J Orthod Dentofacial Orthop, 2007,132(4) :429-438.
  • 10Nakajima A, Sameshima GT, Arai Y, et al. Two-and three-dimensional orthodontic imaging using limited cone beam-computed tomography. Angle Orthod, 2005, 75 ( 6 ) : 895-903.

共引文献62

同被引文献52

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部