摘要
对地下式污水处理厂的结构特征和可燃物及火灾危险性进行了分析,系统阐述了目前全地下式污水处理厂消防设计中存在的问题,并参照其他地下空间的相关设计规范及工程设计中的实际情况,分别从防火分区及人员疏散、室内消火栓的设置、自动灭火系统的设置、气体灭火系统的设置、防排烟系统的设置、火灾自动报警系统及其他消防设施的设置、事故人员疏散等方面提出了针对全地下式污水处理厂的消防设计推荐方案。
Through analyzing the structure characteristics of an underground sewage treatment plant as well as combustibles and fire risk, the problems existing in the fire protection design of the underground sewage treatment plant were systematically illustrated. Based on other relevant design codes of the underground space and the actual situation of engineering design, the fire protection design recommendations of underground sewage treatment plant were proposed in terms of fire compartment and personnel evacuation, setting of indoor fire hydrant, automatic fire extinguishing system, gas fire extinguishing system, smoke control system, automatic fire alarm system and other fire protection facilities as well as personnel evacuation during accident.
出处
《中国给水排水》
CAS
CSCD
北大核心
2016年第16期46-49,共4页
China Water & Wastewater
关键词
地下式污水厂
消防设计
防火分区
消防设施
underground sewage treatment plant
fire protection design
fire compartment
fire protection facilities