摘要
以上海某星级酒店节能改造为例,从建筑实测能耗出发,找出酒店空调系统及生活热水系统能耗的问题,确定节能改造方案并分析实际节能效果,为上海乃至全国类似空调及生活热水冷热源形式的建筑节能改造提供参考。
Taking a hotel building as an example,based on the actual energy consumption and test data,finds out the existing problems related to energy consumption of the HVAC system and domestic hot water system,determines the energy saving reformation measures,and analyses the actual energy saving effect,providing the references for energy saving reformation of similar heat and cold sources of HVAC systems and domestic hot water systems in Shanghai and even in the whole country.
出处
《暖通空调》
北大核心
2016年第8期14-19,共6页
Heating Ventilating & Air Conditioning
基金
上海市科学技术委员会科研计划项目(编号:14DZ1201903)
关键词
实际能耗
综合节能改造
酒店建筑
空调系统
生活热水系统
照明系统
性能测试
actual energy consumption
comprehensive energy saving reformation
hotel building
HAVC system
domestic hot water system
lighting system
performance testing