对于大型医药生产厂房,如何合理划分空调区域是保持稳定的环境条件、节约能源的重要保证。通过分析洁净生产区平面布局和工艺流程,给出了洁净空调系统区域划分的思路,并结合实例进行了分析。
For large pharmaceutical factories,the reasonable division of air conditioning areas is important to guarantee stable environment condition and energy saving.Through analysing the layout and process flow of clean production areas,gives the zoning ideas of clean air conditioning systems,and performs the analysis with an example.
出处
《暖通空调》
北大核心
2016年第8期70-73,共4页
Heating Ventilating & Air Conditioning
关键词
大型药厂
洁净空调系统
区域划分
节能
洁净厂房
large pharmaceutical factory
clean air conditioning system
zoning
energy saving
clean factory