摘要
提出了一种供热系统前馈动态运行调控方案。详细阐述了该方案的理论依据。选取寒冷地区一个实际住宅楼,对2014—2015年度供暖季运行数据进行了监测,通过将调控效果与气候补偿模式、恒定水温模式、分时调控模式的调控效果进行了比较,最终得出新方案可以有效提高室内舒适度,并在保持一定热舒适的条件下,实现节能28%。
Proposes a new feedforward dynamic regulation method for heating systems.Describes the theoretical basis for the regulation method in detail.Chooses an actual heat station as the experiment environment and validates the new method.Monitors the operation data of the heating system in the heating season of 2014-2015.Compares the regulation effect of the new method with those of three regulation methods-climatic compensation method,constant water temperature method and timely regulation method.Concludes that the new method can improve indoor thermal comfort and save 28% of energy in a certain thermal comfort condition.
出处
《暖通空调》
北大核心
2016年第8期120-125,共6页
Heating Ventilating & Air Conditioning
关键词
前馈动态调控
气候补偿调控
恒定水温调控
分时调控
供热系统
feedforward dynamic regulation method
climatic compensation method
constant water temperature method
timely regulation method
heating system