期刊文献+

Quality evaluation of Huaijiao pill by chromatographic fingerprint and simultaneous determination of its major bioactive components 被引量:3

Quality evaluation of Huaijiao pill by chromatographic fingerprint and simultaneous determination of its major bioactive components
下载PDF
导出
摘要 For quality control purpose,an approach of combining chromatographic fingerprint of Huaijiao pill(HP)and simultaneous determination of its major bioactive components was developed using high performance liquid chromatography coupled with diode array detector(HPLC-DAD).For fingerprint analysis,16 peaks were selected as the characteristic peaks to evaluate the similarities of different samples collected from different batches of three manufacturers.The similarities of 17 Huaijiao pill samples were beyond 0.966,indicating that samples from different batches and manufacturers were,to some extent,consistent.Additionally,simultaneous quantification of seven bioactive markers,namely sophoricoside,baicalin,naringin,genistein,rutin,quercetin and 5-O-methylvisammioside,in HP was performed to interpret the quality consistency.The validation of the proposed approach was acceptable,with the accuracy of 90.2%-106.9%in recovery test.The intra-day and inter-day precisions of the method were evaluated and the RSD values were less than 2.81%.The results from the quantitative data showed that the contents of six marker compounds(except for 5-O-methylvisammioside) were quite consistent between batches produced by one manufacturer and significantly distinctive among different manufacturers.The proposed approach was expected to be developed as a powerful tool for the quality control of HP. For quality control purpose,an approach of combining chromatographic fingerprint of Huaijiao pill(HP)and simultaneous determination of its major bioactive components was developed using high performance liquid chromatography coupled with diode array detector(HPLC-DAD).For fingerprint analysis,16 peaks were selected as the characteristic peaks to evaluate the similarities of different samples collected from different batches of three manufacturers.The similarities of 17 Huaijiao pill samples were beyond 0.966,indicating that samples from different batches and manufacturers were,to some extent,consistent.Additionally,simultaneous quantification of seven bioactive markers,namely sophoricoside,baicalin,naringin,genistein,rutin,quercetin and 5-O-methylvisammioside,in HP was performed to interpret the quality consistency.The validation of the proposed approach was acceptable,with the accuracy of 90.2%-106.9%in recovery test.The intra-day and inter-day precisions of the method were evaluated and the RSD values were less than 2.81%.The results from the quantitative data showed that the contents of six marker compounds(except for 5-O-methylvisammioside) were quite consistent between batches produced by one manufacturer and significantly distinctive among different manufacturers.The proposed approach was expected to be developed as a powerful tool for the quality control of HP.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第4期249-255,共7页 药物分析学报(英文版)
关键词 Chromatographic fingerprint HPLC-DAD Huaijiao pill Chromatographic fingerprint HPLC-DAD Huaijiao pill
  • 相关文献

同被引文献29

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部