摘要
针对巴江口水电厂二号机副接力器漏油问题,技术人员从结构上分析漏油原因并提出多项解决方案,通过多次对接力器漏油使用不同方法处理,最终解决此项疑难缺陷。
The cause of oil leakage from pilot servomotor of 2# unit in Bajiangkou Hydropower Plant is studiedand solutions are proposed. The problem is solved at last after different methods of handling are adopted.
出处
《红水河》
2016年第4期119-121,共3页
Hongshui River
关键词
接力器
漏油
巴江口水电厂
servomotor
oil leakage
Bajiangkou Hydropower Plant