期刊文献+

奥氏体不锈钢0Cr18Ni9管板裂纹失效机理分析 被引量:2

The Mechanism Analysis of Crack Failure on Tube Plate Which Material is Austenitic Stainless Steel 0Cr18Ni9
下载PDF
导出
摘要 对出现开裂后的材质为奥氏体不锈钢0Cr18Ni9的管板进行了现场与实验室检测。实验与理论分析结果表明,管板开裂为脆性断裂和正断断裂,裂纹从管板表面首先形成,低温是管板变脆的原因,管程中的介质使管板表面产生氧化层以及温度差所产生的热应变循环作用是裂纹产生及扩展的原因。并对此类管板的制造与使用提出了建议。 Investigated the tests of the tube plate which material is Austenitic Stainless Steel 0Cr18Ni9 field and laboratory.Through experiment and theoretical analysis results show that the tube plate cracking for brittle fracture and normal fault rupture,crack from the surface of the tube plate forming first,low temperature is the cause of the tube plate brittle,medium in tube side make the tube plate surface oxide layer and the temperature difference of thermal cycle of role strain is the cause of crack generation and propagation.And put forward some advices for manufacture and use of such tube plate.
出处 《化工设计通讯》 CAS 2016年第5期115-116,123,共3页 Chemical Engineering Design Communications
关键词 裂纹 金相检验 化学成分 残余应力 热应变 应力腐蚀 crack metallographic examination chemical composition residual stress thermal strain stress corrosion
  • 相关文献