期刊文献+

Experiment on Spray Cooling Performance with Different Additives of Different Mass Fraction 被引量:1

Experiment on Spray Cooling Performance with Different Additives of Different Mass Fraction
下载PDF
导出
摘要 As an efficient cooling method for high heat flux field,spray cooling has a great application potential on aircraft directed energy weapon cooling.Based on previous research results,an experimental system of open-loop spray cooling was established,and the potassium chloride aqueous solutions and ethylene glycol aqueous solutions with different mass fractions were applied to investigate the influence of different additives on spray cooling system performance.Besides,theoretical analysis was conducted according to the droplet breakage principle and the characteristic parameters of fluid mechanics.The results indicate that heat transfer can be enhanced by adding potassium chloride up to a certain concentration and then decrease with higher concentration.Heat transfer is deteriorated with the increase of ethylene glycol concentration.Both of the two additives can reduce the freezing point of the system,and ethylene glycol is preferred to improve the application range of the system in consideration of the corrosion of salt solution. As an efficient cooling method for high heat flux field, spray cooling has a great application potential on aircraft directed energy weapon cooling. Based on previous research results, an experimental system of open-loop spray cooling was established, and the potassium chloride aqueous solutions and ethylene glycol aqueous solutions with different mass fractions were applied to investigate the influence of different additives on spray cooling system performance. Besides, theoretical analysis was conducted according to the droplet breakage principle and the characteristic parameters of fluid mechanics. The results indicate that heat transfer can be enhanced by adding potassium chloride up to a certain concentration and then decrease with higher concentration. Heat transfer is deteriorated with the increase of ethylene glycol concentration. Both of the two additives can reduce the freezing point of the system, and ethylene glycol is preferred to improve the application range of the system in consideration of the corrosion of salt solution.
出处 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2016年第3期375-385,共11页 南京航空航天大学学报(英文版)
关键词 spray cooling potassium chloride ethylene glycol heat transfer coefficient spray cooling potassium chloride ethylene glycol heat transfer coefficient
  • 相关文献

参考文献8

二级参考文献70

共引文献35

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部