摘要 介绍了采用破乳-铁碳微电解-UV/Fenton-序批式生物反应器(SBR)工艺处理二硫氰基甲烷生产废水工程实例。工程实践表明,破乳-铁碳微电解-UV/Fenton预处理工艺可有效降低废水的生物毒性并提高其可生化性,联用SBR生化处理工艺,处理后出水达到污水综合排放标准GB 8978-1996一级标准。 An engineering example of treating methylene bisthiocyanate wastewater by the process of demulsification-microetectrolysis-UV/Fenton-SBR is introduced. It is indicated by the practical operation project that, the pretreatment process of demulsification-microelectrolysis-UV/Fenton can effectively lower the toxicity of wastewater and improve its biodegradability, combined with SBR biological treatment process, the effluent water quality reaches the first grade criteria of the national integrated wastewater discharge standard (GB8978-1996).
出处 《广东化工》 CAS 2016年第15期195-196,202,共3页 Guangdong Chemical Industry
基金 广东省科技计划项目 项目编号2014B070706028
关键词 二硫氰基甲烷废水 UV/FENTON 铁碳微电解 methylene bisthiocyanate wastewater UV/Fenton ferric-carbon microelectrolysis