摘要 目的探讨下肢深静脉联合腹部大血管彩超诊断深静脉血栓的临床效果。方法选取100例下肢深静脉血栓患者的临床及影像学资料进行回顾性分析,患者均在我院进行下肢深静脉的彩超检查,若有血栓已经累及股静脉的患者,则需要对髂静脉和下腔静脉同时进一步逆行扫查。结果 61例处于急性期,21例处于亚急性期,18例处于慢性期。下肢深静脉血栓患者的超声声像图特征是管腔内可探及实性回声,用超声探头加压管腔不能压瘪或消失,脉冲多普勒不能引出血流频谱(或引出不正常的频谱波形)。腹部大血管逆行扫查可见髂静脉和(或)下腔静脉内有血栓、栓瘤等存在而导致下肢深静脉血栓发生。结论下肢深静脉联合腹部大血管彩超诊断深静脉血栓,不仅能够提高下肢深静脉血栓的检出率,而且还能够发现导致患者发生下肢深静脉血栓的病因,对临床治疗方案的选择具有十分重要的指导意义,值得进一步推广应用。
作者 刘香芬
机构地区 侯马市人民医院
出处 《基层医学论坛》 2016年第24期3376-3377,共2页 The Medical Forum
  • 相关文献

参考文献2

二级参考文献13

  • 1Shitrit D,Heyd J,Raveh D,et al.Diagiostic value of the D-dimer testing deep vein thrombosis:improved results by a new assaymethod and by using discriminate levels[J].Thromb Res,2001,102(2):125-130.
  • 2Blann AD,Lip GYH.Venous thromboembolism[J].BM J,2006,332(7535):215-217.
  • 3Greensberg CS,Dcvinc DV,Mc Grac KM,et al.Measurement of p lasmafibrin D-dimer levels with the use or a monoclonal antibody coupled Latex bleeding[J].Am J Clin Pathol,1987,87(1):94-96.
  • 4Mauriello A,Sangio rgi G,Palnfieri G,et al.Hyperfibrinogenemia is associated with specific histocyto logical composition and complications of artherosclerotic carotid plaques in patients affected by transient ischemic attacks Circulation[J].Circulation,2000,101 (7):7443-7746.
  • 5Joffe HV,Goldhaber SZ.Upper-extremity deep vein thrombosis[J].Circulation,2006,106(14):1874-1878.
  • 6Schutgens RE,Esseboom EU,Haas FJ,et al.Usefulness of asemiquantitative D-dimer test for the exclusion of deep venous thrombosis in outpatients[J].Am J Med,2002,112(8):617-621.
  • 7RASKOB G E,SILVERSTEIN R,BRATZLER D W. Surveillance for deep vein thrombosis and pulmonary embolism:recommendations from a national workshop[J].American Journal of Preventive Medicine,2010,(04):502-509.
  • 8TICK L W,TON E,VAN VOORTHUIZEN T. Practical diagnostic management of patients with clinically suspected deep vein thrombosis by clinical probability test,compression ultrasonography,and D-dimer test[J].American Journal of Medicine,2002,(08):630-635.
  • 9GOODACRE S,SAMPSON F,THOMAS S. Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis[J].BMC Medical Imaging,2005.6-18.
  • 10LINKINS L A,STRETTON R,PROBYN L. Interobserver agreement on ultrasound measurements of residual vein diameter,thrombus echogenicity and Dooler venousflow in patients with previous venous thrombosis[J].Thrombosis Research,2006,(03):241-247.