摘要
温州大罗山雷神二次雷达已安装运行8年,2012年起偶尔有信号瞬断出现,2015年开始更加频繁,对航空管制造成了一定的影响。文章详细介绍了故障的排除过程,并对之后的运行提出了建议和措施。
Wenzhou Daluoshan of Raytheon secondary radar has been installed and run for eight years, occasionally there is instantaneous signal broken since 2012 and it happened more frequently in 2015, which had a certain impact on the air traffic control. This paper introduces the elimination process of fault in detail, and puts forward suggestions and measures of the post operation.
出处
《无线互联科技》
2016年第15期8-9,共2页
Wireless Internet Technology
关键词
二次雷达
瞬断
故障定位
secondary radar
transient fault
fault location