摘要 为了获取高线性度微机械陀螺仪常温下的长时漂移特性,该文采用光测法(计算机视觉测试系统)与传统电测法相结合的方法,分别在t=0,25min,120min时测试了微机械陀螺驱动模态的振动特性。最后通过对比分析光测法和电测法的测试结果,获得了微机械陀螺仪的长时漂移特性,并给出了陀螺在常温下产生长时漂移的影响因素。 In order to obtain the long-time drift characteristics of the designed high-linearity MEMS gyroscope under normal temperature, the combination of vision identification method(computer micro vision system) and tradi- tional electrical method is used to test the vibration characteristics of MEMS gyroscope under driving mode at t=0, 25 min,120 min respectively. The long-time drift characteristics of MEMS gyroscope and the influence factors pro- duced the long-time drift are obtained by comparing the test results of the vision identification method and the tradi- tional electrical method.
出处 《压电与声光》 CAS CSCD 北大核心 2016年第4期620-624,共5页 Piezoelectrics & Acoustooptics
基金 总装基金预研资助项目
关键词 微机械陀螺 长时漂移 视觉测量 动态测试 幅频特性 MEMS gyroscope long-time drift vision identification dynamic test amplitude-frequency charac-teristics
  • 相关文献

参考文献4

二级参考文献24

  • 1A.Kourepenis,张沛晗等.微机电系统(MEMS)惯性传感器的性能[J].惯导与仪表,2001(4):1-11. 被引量:2
  • 2周世勤 鲁政 孙道秋.微机械惯性仪表研制现状跟踪研究.航天情报研究报告[R].,2000.40—42.
  • 3张贤达,非平稳信号分析与处理,1998年
  • 4崔锦泰.,小波分析导论,1995年
  • 5A L Hartzell, D J Woodilla. MEMS reliability, characterization,and test[J]. Proceedings of SPIE, 2001, 4558: 1-5.
  • 6C Q Davis, D M Freeman. Using a light microscope to measure motions with nanometer accuracy[J ]. Optical Engineering, 1998,37: 1299-1304.
  • 7C Rembe, L Muller, R S Muller, et al. Full three-dimensional motion characterization of a gimballed electrostatic microactuator[ A].International Reliability Symposium[C]. American: IEEE, 2001.91-98.
  • 8M T Goodrich, J S B Mitchell, M W Orletsky. Approximate geometric pattern matching under rigid motions[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1999, 21(4):371-379.
  • 9A J Parker, R V Kenyon, D Troxel. Comparison of interpolating methods for image resampling[J]. IEEE Transactions on Medical Imaging, 1983, MI-2(1): 31-39.
  • 10Spendley W, Hext G R, Himsworth F R. Sequential Application of simplex designs in optimization and evolutionary operation [ J ].Technometrics, 1962, 4(4): 441-461.

共引文献54

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部