在对燃气锅炉房进行电气设计时,从燃料的相关特性入手,划分锅炉房的爆炸危险区域和范围;同时依照现行规范,并结合实际工程,从供配电、照明、消防联动、防雷接地、设备选型和线路设计等方面进行阐述。
For electrical design of gas-fired boiler room, the areas and scopes of explosion hazardous zone are divided as per relevant features of fuel gases. Meanwhile, as per current specifications and practical projects, description is made from aspects like power supply and distribution, lighting, fire linkage, lightning protection and grounding, equipment model selection and circuit design.
出处
《建筑电气》
2016年第8期46-50,共5页
Building Electricity
关键词
燃气锅炉房
爆炸危险区域划分
供配电
照明
消防自控
设备选型
线路设计
防雷接地
gas-fired boiler room
division of explosion hazardous zone
power supply and distribution
lighting
fire automation
equipment model selection
circuit design
lightning protection and grounding