期刊文献+

机组正常运行时轴加疏水水封失去原因分析 被引量:1

The Normal Operation of the Unit Shaft and Hydrophobic Water Seal to Lose Reason Analysis
下载PDF
导出
摘要 笔者公司两台350 MW超临界机组,每台机组轴封加热器都是单级水封设计,根据以往其他机组的运行经验,目前国内设计轴加疏水水封不论是单级还是多级水封均存在运行不稳定问题,多级水封运行中易发生水封破坏现象,导致轴封冷却器的无水位运行,从而降低机组真空,严重影响机组安全、经济运行。 our company two 350 MW supercritical unit,heater per unit are single stage seal design,according to the operation experiences of other previous units, the current domestic design of shaft and hydrophobic seal whether single level or multilevel water seal are unstable operationproblem,seal failure is liable to occur in the operation of multilevel water seal,cause no waterrunning seal cooler,thereby reducing the vacuum of unit,seriously affecting the unit safety,economic operation.
作者 宁珂
出处 《科技创新导报》 2016年第8期71-72,共2页 Science and Technology Innovation Herald
关键词 火电厂 凝汽式机组 轴封加热器 单级水封 疏水中断 真空 Thermal power plant Condensing steam turbine Shaft seal Water seal Heater Single stage Hydrophobic interrupt
  • 相关文献

参考文献2

  • 1大唐林州热电有限责任公司集控辅机规程[z].2013.
  • 2胡志强.上海汽轮机厂设备说明书[Z].2010.