摘要
目的:比较4种不同口腔金属材料在MRI检查中伪影大小。方法:在标准备牙模型上制作钴铬合金、纯钛、银钯、金钯金属全冠实验组以及二氧化锆全瓷冠对照组,并用25cm×13cm×10cm(长×宽×高)塑料容器蒸馏水包埋后放置于1.5T自旋回波序列T2加权像比较伪影大小。结果:不同金属在同一自旋回波序列中产生伪影大小不同,钴铬合金、纯钛、银钯金属冠的伪影分别为(450±665)、(343±322)、(141±186)mm2,3组间两两比较均存在差异(P<0.05),金钯金属冠与对照组二氧化锆相比伪影大小未见明显差异。结论:4种金属MRI检查中伪影的大小钴铬合金>纯钛>银钯合金>金钯合金。
Objective:To compare the MRI artifacts of four different dental metal materials,providing clinical evidence for prosthodontic doctors.Methods:Full crowns of Co-Cr alloy,pure titanium,silver palladium,and gold palladium were made according to a standard model.Full crown of zirconium dioxide was taken as control.All crowns were embedded in a 13 cm × 25cm×10cm(length x width x height)plastic container filled with distilled water.Artifacts were compared on the T2-weighted images in 1.5Tspin echo sequences.Results:Different materials showed different artifacts in the same spin echo sequence.Artifacts of Co-Cr alloy,pure titanium,silver palladium crownswere(450±665),(343±322),(141±141)respectively.There were significant differences between them(P0.05).There was no significant difference between gold palladium group and zirconium dioxide group.Conclusion:MRI artifacts of the four materials in descending order were as follows:Co-Crpure titaniumsilver palladiumgold palladium.
出处
《口腔医学研究》
CAS
CSCD
北大核心
2016年第8期812-815,共4页
Journal of Oral Science Research
基金
国家自然科学基金青年基金项目(编号:2015211C111)