期刊文献+

An empirical study on vortex-generator insert fitted in tubular heat exchangers with dilute Cu–water nanofluid flow 被引量:3

An empirical study on vortex-generator insert fitted in tubular heat exchangers with dilute Cu–water nanofluid flow
下载PDF
导出
摘要 The heat transfer enhancement(HTE) in tubular heat exchangers fitted with vortex-generator(VG) inserts is experimentally investigated. The studied four parameters and ranges are: winglets-pitch ratio(1.33, 2.67, and 4),winglets-length ratio(0.33, 0.67, and 1), winglets-width ratio(0.2, 0.4, and 0.6), and Reynolds number(5200to 12200). The testing fluids are the water and Cu–water nanofluid at the volumetric fraction of 0.2%. The results obtained on HTE, pressure drop, and performance evaluation criterion(PEC) are compared with those for water in a smooth tube. It is found that the VG inserts with lower winglets-pitch ratio and higher winglets-length/width ratios present higher values of HTE and pressure drop. Over the range studied, the maximum PEC of 1.83 is detected with the Cu–water nanofluid inside the tube equipped with a VG insert at the winglets-width ratio of0.6 for the maximum Reynolds number, when the heat transfer rate and pressure drop are 1.24 times and 2.03 times of those in the smooth tube. Generalized regression equations of the Nusselt number, friction factor, and PEC are presented for the tubular heat exchangers with the VG inserts for both water and Cu–water nanofluid.It is concluded that the main advantage of the VG inserts is their simple fabrication and considerable performance, particularly at higher Reynolds number. The heat transfer enhancement (HTE) in tubular heat exchangers fitted with vortex-generator (VG) inserts is ex- perimentally investigated. The studied four parameters and ranges are: winglets-pitch ratio (1.33, 2.67, and 4), winglets-length ratio (0.33, 0.67, and 1), winglets-width ratio (0.2, 0.4, and 0.6), and Reynolds number (5200 to 12200). The testing fluids are the water and Cu-water nanofluid at the volumetric fraction of 0.2%. The results obtained on HTE, pressure drop, and performance evaluation criterion (PEC) are compared with those for water in a smooth tube. It is found that the VG inserts with lower winglets-pitch ratio and higher winglets-length/width ratios present higher values of HTE and pressure drop. Over the range studied, the maximum PEC of 1.83 is detected with the Cu-water nanofluid inside the tube equipped with a VG insert at the winglets-width ratio of 0.6 for the maximum Reynolds number, when the heat transfer rate and pressure drop are 1.24 times and 2,03 times of those in the smooth tube. Generalized regression equations of the Nusselt number, friction factor, and PEC are presented for the tubular heat exchangers with the VG inserts for both water and Cu-water nanofluid. It is concluded that the main advantage of the VG inserts is their simple fabrication and considerable performance, particularly at higher Reynolds number.
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第6期728-736,共9页 中国化学工程学报(英文版)
关键词 Heat transfer enhancementVortex-generator insertNanofluid Turbulent flowCorrelation 管壳式换热器 涡流发生器 纳米流体 安装 流动 翼梢小翼 雷诺兹数
  • 相关文献

参考文献26

  • 1S. Chokphoemphun, M. Pimsarn, C. Thianpong, P. Promvonge, Heat transfer aug- mentation in a circular tube with winglet vortex generators, Chin.J, Chem. Eng. 23 (4) (2015) 605-614.
  • 2kS. Sundar, M.K. Singh, Convective heat transfer and friction factor correlations of nanofluid in a tube and with inserts: a review, Renew. Sust. Energ. Rev. 20 (2013) 23-35.
  • 3D. Kim, Y. Kwon, Y. Cho, C. Li, S. Cheong, Y. Hwang, J. Lee, D. Hong, S. Moon, Convective heat transfer characteristics of nanofluids under laminar and turbulent flow conditions, Curt. Appl. Phys. 9 (2009) 119-123.
  • 4W. Duangthongsuk, S. Wongwises, An experimental study on the heat transfer performance and pressure drop ofTiO2-water nanofluids flowing under a turbulent flow regime, Int.J. Heat Mass Transf. 53 (2010) 334-344.
  • 5M. Chandrasekar, S. Suresh, A. Chandra Bose, Experimental studies on heat transfer and friction factor characteristics of Al203/water nanofluid in a circular pipe under laminar flow with wire coil inserts, Exp. Thermal Fluid $ct 34 (2) (2010) 122-130.
  • 6L.S. Sundar, K.V. Sharma, Turbulent heat transfer and friction factor of A1203 Nanofluid in circular tube with twisted tape inserts, Int. J. Heat Mass Trnnsf. 53 (7-8) (2010) 1409-1416.
  • 7M.T. Naik, G.IL Janardana, L.S. Sundar, Experimental investigation of heat transfer and friction factor with water-propylene glycol based CuO nanofluid in a tube with twisted tape inserts, Int. Commun. Heat Mass Transfer 46 (2013) 13-21.
  • 8M.C.S. Reddy, V.V. Rao, Experimental investigation of heat transfer coefficient and friction factor of ethylene glycol water based Ti02 nanofluid in double pipe heatexchanger with and without helical coil inserts, Int. Commun. Heat Mass Transfer 50 (2014) 68-76.
  • 9S. Suresh, K.P. Venkitaraj, P. Selvakumar, M. Chandrasekar, A comparison of thermal characteristics of Al203/water and CuO/water nanofluids in transition flow through a straight circular duct fitted with helical screw tape inserts, Exp. Thermal Fluid Sci. 39 (2012) 37-44.
  • 10M. Saeedinia, M.A. Akhavan-Behabadi, M. Nasr, Experimental study on heat transfer and pressure drop of nanofluid flow in a horizontal coiled wire inserted tube under constant heat flux, Exp. Thermal Fluid Sci. 36 (2012) 158-168.