期刊文献+

硬膜外分娩镇痛对胎儿脐动脉和大脑中动脉血流的影响 被引量:20

Effects of labor analgesia on maternal and neonatal outcomes monitored using Doppler ultrasound
下载PDF
导出
摘要 目的运用多普勒超声观察硬膜外分娩镇痛对胎儿脐动脉和大脑中动脉血流的影响。方法选择要求硬膜外分娩镇痛的产妇59例(R组),同时选取拒绝分娩镇痛产妇25例(N组)。记录产妇产程时间、出血量、分娩方式、新生儿情况。当宫口开至2 cm时,R组记录镇痛前(T0)、镇痛后15 min(T1)、镇痛后30 min(T2)和镇痛后60 min(T3)胎儿大脑中动脉、脐动脉阻力指数(RI)、搏动指数(PI)和最大峰值血流速度/舒张末期血流速度(S/D),N组在相同时间间隔记录上述参数。结果两组产妇产程时间、出血量及分娩方式差异无统计学意义。T0~T2时,R组胎儿大脑中动脉、脐动脉PI和S/D有下降趋势,大脑中动脉RI有增加趋势,但组内差异无统计学意义。N组在各时点无明显改变,组间差异无统计学意义。结论硬膜外分娩镇痛对母婴无明显影响,不良反应少,有很好的临床应用价值。 Objective To observe the effects of labor analgesia on the maternal and neonatal outcomes using Doppler ultrasound. Methods Fifty-nine primipara who required labor analgesia were included into group R,while 25 primipara who rejected labor analgesia were included into group N. The duration of labor process,bleeding volume,method of labor and the neonatal outcomes were recorded and compared between the two groups. Moreover,pulsatility index( PI),resistance index( RI),and systolic / diastolic( S/D) were also recorded at the time before analgesia( T0),15 min after analgesia( T1),30 min after analgesia( T2) and 60 min after analgesia( T3) between the two groups. At the same time,RI,PI and S/D were also recorded in the group N. Results There were no significant differences in the duration of labor process,bleeding volume,method of labor and neonatal outcomes. And patients in the group R presented a decreasing trend in PI and S / D as well as an upward trend in RI after labor analgesia,but the differences were not significant. Furthermore,the changes in each index of the patients in group N were not significant,either. Conclusion Epidural labor analgesia does not affect maternal and neonatal outcomes,which can be safely used in clinic with little side effects.
出处 《临床麻醉学杂志》 CAS CSCD 北大核心 2016年第8期769-771,共3页 Journal of Clinical Anesthesiology
基金 南京医科大学科技发展基金面上项目(2013NJMU124)
关键词 硬膜外分娩镇痛 多普勒超声 大脑中动脉 脐动脉 Epidural labor analgesia Doppler ultrasound Middle cerebral artery Umbilical artery
  • 相关文献

参考文献6

  • 1Valentin M, Ducarme G, Ceecaldi PF, et al. Uterine artery, umbilical, and fetal cerebral Doppler velocities after epidural analgesia during labor. Int J Gynaecol Obstet, 2012, 118(2) : 145-148.
  • 2冯善武,徐世琴,王娴,王楠,雷黎明,沈晓凤.规律间断给药用于硬膜外分娩镇痛对产妇产间发热的影响[J].临床麻醉学杂志,2015,31(9):858-861. 被引量:45
  • 3寿仕新,林纪光,陈利琼,王艳杰.胎儿脐动脉和大脑中动脉阻力指标比值预测胎儿宫内窘迫的价值[J].医学影像学杂志,2009,19(6):664-666. 被引量:25
  • 4Chen LK, Yang YM, Yang YH, et al. Doppler measurement of the changes of fetal umbilical and middle cerebral artery velocimetric indices during continuous epidural labor analgesia. Reg Anesth Pain Med, 2011,36 (3):249-255.
  • 5Fratelli N, Prefumo F, Andrico S, et al. Effects of epidural analgesia on uterine artery Doppler in labour. Br J Anaesth, 2011,106 (2) : 221-224.
  • 6Kachewar SG, Gandage SG. The foetal rMindr as a reflection of its inner self evidence from colour doppler ultrasound of foetal MCA. Mens Sana Monogr, 2012,10(1) : 98-108.

二级参考文献18

  • 1Krampl E,Chalubinski K,Schatten C,et al.Dose acute hypoxia cause fetal arterial blood flow redistribution[J].Ultrasound Obstet Gynecol,2001,18:175-178.
  • 2Chandran R,Serra-Serra V,Susan M,et al.Fetal cerebral Doppler in the recognition of fetal compromise[J].Br J Obster Gynaecol,1993,100:139-144.
  • 3Mare W Suterlin,Birgit Seel Bach Gobel,Martink O Ehler,et al.Doppler ultrasonographic evidence of interpartern brainsparing defect in fetuses with low oxygen saturation according to pulse oximetry[J].Am J Obstet Gynercol,1999,181:216-218.
  • 4Pardi G,Marconi AM,Cetin I.Placental-fetal interrelation ship in IUGR fetuses-a review[J].Placenta,2002,23,136-141.
  • 5乐杰.妇产科学[M].北京:人民卫生出版社,1999.254.
  • 6韩阳 李燕萍 邱继红 等.彩色多普勒检测胎儿肾动脉血流预测胎儿宫内缺氧.中国优生与遗传杂志,2001,9(1):63-63.
  • 7Segal S. Labor epidural analgesia and maternal fever. Anesth Analg, 2010, 111(6) : 1467-1475.
  • 8Riley LE, Celi AC, Onderdonk AB, et al. Association of epi- dural-related fever and noninfectious inflammation in term la-bor. Obstet Gynecol, 2011, 117(3) :588-595.
  • 9Lim Y, Sia AT, Ocampo C, Automated regular boluses for epidural analgesia: a comparison with continuous infusion. Int J Obstet Anesth, 2005, 14(4);305-309.
  • 10Wong CA, Ratliff JT, Sullivan JT, et al. A randomized com- parison of programmed intermittent epidural bolus with con- tinuous epidural infusion for labor analgesia. Anesth Analg, 2006, 102(3) :904-909.

共引文献68

同被引文献161

引证文献20

二级引证文献191

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部