摘要
利用Matlab/Simulink对现有的3种AT供电模式牵引网进行仿真,模拟正常负载和短路故障的情况,得到不同供电模式下贯通地线电流的变化。再带入磁耦合计算模型,得到信号电缆的感应电动势。仿真结果表明:感应电动势均未超过规定值,但新模式下故障时信号电缆的感应电动势达到90 V,该值偏大,需加设防护装置。
The through earthing wire current variations under different power supply modes have been obtained after simulation of existed 3 types of AT power supply modes made by application of Matlab/Simulink, under circumstances of normal load and short circuit load; and the inductive electromotive force of the signal cable is also obtained after input of magnetic coupling calculation model, the simulation results show that: all inductive electromotive forces are not beyond the rated values, however, the electromotive force of signal cable has reached 90 V when it is faulty under new mode, the value is relatively high, and protection devices are required to be set.
出处
《电气化铁道》
2016年第4期47-50,共4页
Electric Railway
关键词
信号电缆
磁影响
AT供电模式
贯通地线
感应电动势
Signal cable
magnetic effect
AT power supply mode
through earthing wire
inductive electromotive force