期刊文献+

北京地区多种光伏组件发电性能对比实验研究 被引量:18

Comparative experimental study on the power generation performance of photovoltaic modules in Beijing AREA
下载PDF
导出
摘要 该课题组设计建造了一座光伏试验电站,对单晶硅光伏组件、多晶硅光伏组件、非晶硅光伏组件、铜铟镓硒光伏组件和碲化镉光伏组件进行长期监测,对监测数据进行统计并分析了温度、弱光和湿度对不同光伏组件的影响,设计了阴影遮挡试验和灰尘清洗试验。研究表明,薄膜光伏组件的温度效应优于晶硅光伏组件,其输出功率损失低于晶硅光伏组件;对于晶硅光伏组件由于表面积尘和阴影遮挡而引起的输出功率损失要高于薄膜光伏组件;而弱光和湿度对光伏组件发电性能的影响没有明显差异。通过分析试验电站的监测数据,发现铜铟镓硒光伏组件单位装机容量的发电量最高,其发电量高出多晶硅光伏组件5.72%,而次于铜铟镓硒光伏组件发电能力的是单晶硅光伏组件和多晶硅光伏组件。 The field test of the mono-crystalline silicon module, the poly-crystalline silicon module, the amorphous silicon module, the copper indium gallium selenium module and the cadmium telluride module have been designed and have been carried for long-term in this paper. The impacts on the different modules of the temperature, weak light and humidity factors were studied by analyzing the test data. The shadow test and the dust cleaning test were designed independently. The research shows that the effect of temperature on the thin film modules is smaller than that of the crystalline silicon modules, while the effects of the weak light and the humidity have no significant difference in both of the thin film modules and the crystalline silicon modules. By analyzing the data of the test station, it was found that the power generation of a copper indium gallium selenium module is the highest and is much more than 5.72% of the poly-silicon module, followed by the mono-crystalline silicon module and the poly-silicon module.
作者 张传升
出处 《可再生能源》 CAS 北大核心 2016年第8期1117-1123,共7页 Renewable Energy Resources
基金 北京市科技创新基地培育与发展工程专项(Z131110002813120)
关键词 光伏组件 对比实验 温度效应 阴影效应 灰尘影响 PV module Comparative experiment temperature effect shadow effect dust effect
  • 相关文献

参考文献13

  • 1Li DHW,Cheung KL,Lam TNT,et al.A study of grid-connected photovoltaic(PV)system in Hong Kong[J].Appl Energy,2012,90(1):122-128.
  • 2Padmavathi K,Daniel SA.Performance analysis of a 3MWp grid connected solar photovoltaic power plant in India[J].Energy Sustain Dev,2013,17(6):615-625.
  • 3Kumar KA,Sundareswaran K,Venkateswaran PR.Performance study on a grid connected 20 k Wp solar photovoltaic installation in an industry in Tiruchirappalli(India)[J].Energy Sustain Dev,2014,23(15):294-304.
  • 4Ayompe LM,Duffy A,Mc Cormack SJ,et al.Measured performance of a 1.72 k W rooftop grid connected photovoltaic system in Ireland[J].Energy Convers Manage,2011,52(2):816-825.
  • 5Saeed Edalati,Mehran Ameri,Masoud Iranmanesh.Comparative performance investigation of mono-and poly-crystalline silicon photovoltaic modules for use in grid-connected photovoltaic systems in dry climates[J].Applied Energy,2015,160(9):255-265.
  • 6陈菊芳,沈辉,李军勇,杨灼坚,刘勇,梁学勤.广州地区薄膜光伏并网电站性能研究[J].太阳能学报,2011,32(1):45-48. 被引量:9
  • 7张臻,沈辉,李达.局部阴影遮挡的太阳电池组件输出特性实验研究[J].太阳能学报,2012,33(1):5-12. 被引量:32
  • 8冯志诚,王亚辉,吴露露,王召阳,王晶晶,田瑞.局部阴影条件下光伏组件性能实验研究[J].太阳能学报,2015,36(2):392-398. 被引量:10
  • 9A Al Otaibi,A Al Qattan,F Fairouz,et al.Performance evaluation of photovoltaic systems on Kuwaiti schools'rooftop[J].Energy Conversion and Management,2015,95(5):110-119.
  • 10Monto Mani,Rohit Pillai.Impact of dust on solar photovoltaic(PV)performance:Research status,challenges and recommendations[J].Renewable and Sustainable Energy Reviews,2010,14(9):3124-3131.

二级参考文献36

  • 1翟载腾,程晓舫,丁金磊,查珺,茆美琴.电性参数对串联太阳电池失配损失的影响[J].中国电机工程学报,2006,26(z1):42-45. 被引量:7
  • 2Am Al-Ashwal. Photovoltaic system for transmission substation application[J]. Renewable Energy, 1998, 14(1-4): 157- 163.
  • 3Crispin Aubrey. Solar Generation IV-2007 [ M]. Green Peace and EPIA, 2007, 34.
  • 4Asl-Soleimani E, Farhangi S, Zabihi M S. The effect of tilt angle, air pollution on performance of photovoltaic systems in Tehran[J]. Renewable Energy, 2001, 24(3-4): 459-468.
  • 5Aristizabal A J, Gordillo G. Performance monitoring results of the first grid-connected BIPV system in Colombia[ J]. Renew- able Energy, 2008, 33(11): 2475-2484.
  • 6Divigalpitiya W M R. Temperature dependence of the photo- voltaic characterics of silicon MIS solar cell[J]. Solar Energy Materials, 1989, 18(5): 253-262.
  • 7Tian W, Wang Y P, Ren J B, et al. Effect of urban climate on building integrated photovohaics performance [ J]. Energy Conversion and Management, 2007, 48(1): 1-8.
  • 8Green M A. Solar Cells: Operating principles, technology and system application[ M]. Englewood Cliffs, N.J. : Prentice- Hall, Inc, 1986, 114.
  • 9Verschraegen J, Burgelman M, Penndorf J. Temperature de- pendence of the diode ideality factor in CulnS2-on-Cu-tape so- lar cells[J]. Thin Solid Films, 2005, 480-481: 307-311.
  • 10Riad A S, Khalil S M, Darwish S. Effect of temperature on photoconducfion and low frequency capacitance measurements on β-CuPc photovoltaic cells[J]. Thin Solid Films, 1994, 249(2) : 219-223.