期刊文献+

Comparison of concentration methods for detection of hepatitis A virus in water samples 被引量:1

Comparison of concentration methods for detection of hepatitis A virus in water samples
原文传递
导出
摘要 Hepatitis A virus is a pathogen associated with water pollution.Contaminated drinking water can cause hepatitis A outbreaks,lead to economic losses,and even threaten human lives.It is difficult to detect low levels of hepatitis A virus in water,so the virus must be concentrated in order to quantify it accurately.Here,we present a simple,rapid,efficient technique for the concentration and detection of hepatitis A virus in water.Our data showed that adding phosphate-buffered saline to the water,pre-filtering the water,and adding Trizol reagent directly to the filtration membrane can significantly improve concentration efficiency.Of three types of filtration membranes studied(mixed cellulose ester membrane,polyvinylidene fluoride membrane,and nylon membrane),the concentration efficiency using mixed cellulose ester membrane with a 0.1-μm pore size was the highest,reaching 92.62 ± 5.17%.This method was used to concentrate hepatitis A virus in water samples from Donghu Lake.Using SYBR Green real-time reverse transcription polymerase chain reaction analysis,the detection sensitivity of this method reached 10~1 copies/μL and its concentration efficiency reached 79.45 ± 9.88%. Hepatitis A virus is a pathogen associated with water pollution. Contaminated drinking water can cause hepatitis A outbreaks, lead to economic losses, and even threaten human lives. It is difficult to detect low levels of hepatitis A virus in water, so the virus must be concentrated in order to quantify it accurately. Here, we present a simple, rapid, efficient technique for the concentration and detection of hepatitis A virus in water. Our data showed that adding phosphate-buffered saline to the water, pre-filtering the water, and adding Trizol reagent directly to the filtration membrane can significantly improve concentration efficiency. Of three types of filtration membranes studied (mixed cellulose ester membrane, polyvinylidene fluoride membrane, and nylon membrane), the concentration efficiency using mixed cellulose ester membrane with a 0.1-1Jm pore size was the highest, reaching 92.62 + 5.17%. This method was used to concentrate hepatitis A virus in water samples from Donghu Lake. Using SYBR Green real-time reverse transcription polymerase chain reaction analysis, the detection sensitivity of this method reached 101 copies/μL and its concentration efficiency reached 79.45 + 9.88%.
出处 《Virologica Sinica》 SCIE CAS CSCD 2016年第4期331-338,共8页 中国病毒学(英文版)
基金 supported by grants from the National Science and Technology Support Program (No.2013BAK12B05) the National Basic Research Program (No.2010CB530301) the National Natural Science Foundation of China (No.31070141,31100132)
关键词 CONCENTRATION filtration membrane hepatitis A virus mixed cellulose ester(MCE) membrane water samples concentration filtration membrane hepatitis A virus mixed cellulose ester (MCE)membrane water samples
  • 相关文献

参考文献2

二级参考文献41

共引文献7

同被引文献2

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部