摘要 One assumption underlying the conventional dilatometric analysis based on the lever rule is that the volume of the specimen changes isotropically during phase transformation,which conflicts with the irreversible length change shown in actual measurements.The contribution of this irreversible effect to the dilation data of pure iron upon heating and cooling was respectively quantified via conversion equations based on lattice parameters.A model considering the elastic strain and creep deformation was established for both the interpretation of the irreversible volume change and the discrepancy between the results measured by a dilatometer and a micrometer. One assumption underlying the conventional dilatometric analysis based on the lever rule is that the volume of the specimen changes isotropically during phase transformation,which conflicts with the irreversible length change shown in actual measurements.The contribution of this irreversible effect to the dilation data of pure iron upon heating and cooling was respectively quantified via conversion equations based on lattice parameters.A model considering the elastic strain and creep deformation was established for both the interpretation of the irreversible volume change and the discrepancy between the results measured by a dilatometer and a micrometer.
出处 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2016年第8期828-833,共6页 钢铁研究学报(英文版)
基金 Item Sponsored by Key Projects in National Science and Technology Pillar Program of China(2013BAE07B00) National Natural Science Foundation of China(51474142) Program for Professors of Special Appointment(Eastern Scholar)at Shanghai Institutions of Higher Learning of China(2012)
关键词 irreversible Transformation micrometer interpretation specimen lever length creep ferrite shrinkage irreversible Transformation micrometer interpretation specimen lever length creep ferrite shrinkage
  • 相关文献

参考文献17

  • 1Y. Chen, G. A. Chen, J. Iron Steel Res. Int. 10 (2003) No. 4 46-48.
  • 2J.L. Zhao, Y. Xi, W. Shi, L. I.i, J. Iron Steel Res. lnt. 19 (2012) No. 4, 57 62.
  • 3D. Li, Y. A. Min, X. C. Wu, J. Iron Steel Res. Int. 17 (2010) No. 11, 62-66.
  • 4C. Garci, F. G. Caballero, C. Capdevila, L. F. Alvarca, Mater. Charact. 48 (2002) 101 111.
  • 5R. Kapoor, L. Kumar, I. S. Batra, Mater. Sci. Eng. A 352 (2003) 318 324.
  • 6J. Z. Zhao, C. Mesplont, C. D. Cooman, .]. Mater. Process. Tcchn- ol. 129 (2002) 345-348.
  • 7S. Choi, Mater. Sci. Eng. A 363 (2003) 72-80.
  • 8D.W. Suh, C.S. Oh, H.N. Han, S.J. Kim, Metall. Mater. Trans. A 38 (2007) 296S 2973.
  • 9E. Pagounis, E. Haimi, J. Pietiktiinen, M. Talvitie, S. Vahvaselkti, V. K. Lindroos, Scripta Mater. 34 (1996) 407-413.