采用气浮+生化+气浮组合提标改造工艺处理印染废水。运行结果表明,好氧池出水水质较好,COD去除率可达80%以上,处理后的出水水质COD<200 mg/L,满足纺织染整工业水污染物排放纳管标准。
An airfioatation + biochemistry + airfioatation combined process was adopted to treat the printing and dyeing wastewater. The results show that the removal efficiency of COD in aerobic tank is up to 90% and more. After the further treatment, the COD concentration of the effluent can be less than 200 mg/L, which would meet the requirement of wastewater discharge for Textile and dyeing industry.