期刊文献+

基于泄漏监测系统的直埋热水管道工程质量控制 被引量:2

Monitoring System Based Quality Control for Hot Water Pipeline
下载PDF
导出
摘要 文中通过对管道泄漏监测系统及其施工和检测方法的研究,结合直埋热水管道的施工过程检验,提出了利用管道泄漏监测系统在工程施工过程中的测试结果发现直埋热水管道外护管及补口的密封性缺陷的方法,进而提出利用泄漏监测系统对直埋热水管道工程实施质量控制,有助于提高热水管网工程建设质量。 By investigation of leakage monitoring system and its method of installation and test, combining the work process inspection of installation of hot water pipeline, the method to find the failures of tightness of casing pipes and repaired mouth by pipeline leak monitoring system in the process of engineering construction was proposed, and then the method for quality control of installation of hot water pipelines using leak monitoring system was proposed, which may help to promote the engineering quali- ty of hot water pipeline.
出处 《管道技术与设备》 CAS 2016年第2期55-57,共3页 Pipeline Technique and Equipment
关键词 泄漏监测 直埋热水管网 质量控制 外护管 补口 密封 leakage monitoring directly buried hot water pipeline quality control casing pipe repaired mouth sealing
  • 相关文献

参考文献5

  • 1中华人民共和国建设部.城镇供热管网工程施工及验收规范:CJJ28--2004[S].北京:中国建筑工业出版社,2004:11-12.
  • 2Pipeguard Momitoring System AB.PGMS User Manual [ Z ], 2013.
  • 3CEN.Distriet heating pipes-Preinsulated bonded pipe systems for directly buried hot water networks-Surveillance systems: EN14419:2009[S], 2009.
  • 4中华人民共和国住房和城乡建设部.城镇供热直埋热水管道技术规程:CJJ/T81-2013[S].北京:中国建筑工业出版社,2013.
  • 5胡彦彬.供热管道泄漏监测系统选择与实施[Z],2015.

共引文献1