文中通过对管道泄漏监测系统及其施工和检测方法的研究,结合直埋热水管道的施工过程检验,提出了利用管道泄漏监测系统在工程施工过程中的测试结果发现直埋热水管道外护管及补口的密封性缺陷的方法,进而提出利用泄漏监测系统对直埋热水管道工程实施质量控制,有助于提高热水管网工程建设质量。
By investigation of leakage monitoring system and its method of installation and test, combining the work process inspection of installation of hot water pipeline, the method to find the failures of tightness of casing pipes and repaired mouth by pipeline leak monitoring system in the process of engineering construction was proposed, and then the method for quality control of installation of hot water pipelines using leak monitoring system was proposed, which may help to promote the engineering quali- ty of hot water pipeline.