期刊文献+

二滩水电站水工金属结构安全检测及评估 被引量:2

Safety inspection and evaluation of hydraulic metal structure at Ertan hydropower station
下载PDF
导出
摘要 水工金属结构安全关系到水电站安全度汛和水库的正常运行调度。对水工金属结构进行安全检测和评估是及时发现问题和隐患、保障水电站运行安全和经济效益的重要手段。笔者介绍了二滩水电站水工金属结构安全检测范围选择、检测内容及方法、检测和计算成果、安全评估等内容,提出了保障水工金属结构安全运行的建议。 The safety of hydraulic metal structures is crucial for flood periods and reservoir operation.Safety inspection and evaluation of hydraulic metal structure may help to reveal the problems immediate-ly and ensure the safety and economic benefit of the hydropower station.In this paper,the author intro-duced the inspection range,content,method,results and safety evaluation for hydraulic metal structuresof Ertan hydropower station,and put forward the suggestions to ensure the safety operation of hydraulicmetal structure.
出处 《大坝与安全》 2016年第3期60-64,共5页 Dam & Safety
关键词 二滩水电站 金属结构 安全检测 评估 Ertan hydropower station metal structures safety inspection evaluation
  • 相关文献

参考文献2

  • 1DL/T835-2003水工钢闸门和启闭机安全检测技术规程[S].
  • 2魏晓斌,吴迪,刘礼华.二滩水电站大坝安全第二次定期检查水工金属结构检测报告[R].武汉:武汉大学,2014.

共引文献7

同被引文献15

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部