期刊文献+

基于AGET芯片的MPGD探测器前端电子学设计 被引量:4

A Front-End Design of Readout Electronics for MPGD Based on AGET
下载PDF
导出
摘要 本文介绍了一种基于AGET芯片的微结构气体探测器前端电子学系统。该系统采用模块化结构,单个模块具有4片AGET芯片,可同时接收256路探测器信号;通过多个模块并行工作,可处理更大规模的探测器通道。该系统具有多通道、高集成度、低噪声和可扩展等优点,可适应微结构气体探测器等的读出需求。经电子学测试,该系统在不同动态范围,不同达峰时间的积分非线性均小于2%,等效噪声电荷小于1 700 e。 This study introduces a front -end design of the readout electronics for Micro -Pattern Gas Detectors based on AGET chip. Modular structure is adopted in this system, a single module integrates four AGET ehips ineluding 256 detector channels. Multiple modules can be easily combined to inerease the number of detector channels. With large number of channels, high integration, low power eonsumption and scalability, this system can effectively adapt to readout el.ectronies of Micro - Pattern Gas Detector and others. After testing, the INL of different peaking time is better than 2% and the noise is better than 1700e in different dynamic range of the design.
出处 《核电子学与探测技术》 CAS 北大核心 2016年第4期430-434,443,共6页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金优秀青年科学基金(11222552)资助
关键词 AGET 微结构气体探测器 多通道读出 AGET Micro - Pattern Gas Detector readout system
  • 相关文献

参考文献9

  • 1谢一冈.微结构气体探测器及其应用[J].现代物理知识,2011,23(5):16-24. 被引量:2
  • 2French M J, Jones L L, Morrissey Q, et al. Design and results from the APV25, a deep sub - micron CMOS front - end chip for the CMS tracker[J]. Nu- clear Instruments and Methods in Physics Research Section A :Accelerators, Spectrometers, Detectors and Associated Equipment, 2001,466 (2) :359 - 365.
  • 3Aspell P, Anelli G, Chalmet P, et al. VFAT2: A front- end system on chip providing fast trigger infor- mation, digitized data storage and formatting for the charge sensitive readout of multi - channel silicon and gas particle detectors[J]. Proc. of the Topical Work- shop on Electronics for Particle Physic ( TWEPP2007), Prague, Czech Republic, 2007, 21 : 292 - 296.
  • 4Calvet D. A versatile readout system for small to me- dium scale gaseous and silicon detectors ~ J J. Nuclear Science, IEEE Transactions on, 2014, 61 ( 1 ) :675 - 682.
  • 5Anvar S, Baron P, Blank B, ct M. AGET, the GET front - end ASIC, for the readout of the Time Projec- tion Chambers used in nuclear physic experiments [C]. Nuclear Science Symposium and Medical Ima- ging Conference ( NSS/MIC ), IEEE, 2011 : 745 - 749.
  • 6Baron P, Delagnes E. AGET datasheet [DB/OL]. Scalay, 2013.
  • 7Martoiu S, Muller H, Tarazona A, et al. Develop- ment of the scalable readout system for micro - pattern gas detectors and other applications [J]. Journal of Instrumentation, 2013, 8(3) : C03015.
  • 8Zheng Q B, Liu S B, Tian J, et al. A Prototype Scal- able Readout System for Micro- pattern Gas Detectors [J]. arXiv prepfint arXiv:1602.01437, 2016.
  • 9张德良,封常青,张俊斌,等.OnboardCalibrationCircuit for the DAMPE BGO Calorimeter Front - end Electronics ~J]. Chinese physics C,201.

共引文献1