摘要
比较了并网型光伏发电站的中性点接地方式,并以某光伏电站为例,计算中性点接地电阻值,为今后工程提供参考。
Compared the neutral point grounding modes applied to grid-connected PV power station and Took a PV power station as an example to calculate the ohmic value of the neutral point grounding that might provide a reference for future engineering projects.
出处
《上海电气技术》
2016年第3期12-14,共3页
Journal of Shanghai Electric Technology
关键词
光伏发电站
并网
中性点
接地
PV Power Station
Grid-Connected
Neutral Point
Grounding