摘要
某核电厂热水加热系统(VYS)调试过程中采用VEGAPULS 62导波雷达液位计对波动箱液位进行精确测量,为防止系统冲洗过程中除盐水溢出波动箱和除盐水补给阀频繁动作,对导波雷达液位计参数进行优化。参数优化后的冲洗试验表明,波动箱液位正常,雷达液位计工作正常,可以很好地对波动箱液位进行监测。
A nuclear power plant applied VEGAPULS 62 guide radar liquid level meter on hot water heating system to precisely measure surge tank liquid level. To prevent demineralized water run over surge tank,and supply valve over-frequently act while wash clean,the liquid level meter parameter was improved. After improvement,liquid level in surge tank remains normal,liquid level meter work properly.
出处
《华电技术》
CAS
2016年第8期1-2,共2页
HUADIAN TECHNOLOGY
基金
上海市青年科技启明星基金(14QB1400300)
关键词
热水加热系统
导波雷达液位计
波动箱
参数优化
hot water heating system
guide radar liquid level meter
surge tank
parameter improvement