基于TASK功率模型的电能表动态误差测试方法 被引量:17

TASK Power Model Based Dynamic Error Testing for Electricity Meter
下载PDF
导出
摘要 该文首先采用连续空间函数序列的信号分解方法,建立了动态测试电压、电流和功率的函数序列模型。其次,提出了一种面向时间过程的三幅值键控(ternary amplitude shift keying,TASK)动态测试功率模型,给出了TASK动态功率的产生方案;在此基础上,定义了单向与双向功率的多种动态负荷模式。最后,基于所提出的理论方法,搭建了电能表动态误差测试系统,测试了国内外不同厂家多种电能表的动态误差,验证了TASK动态测试信号模型与测试方法的正确性。 Using the signal decomposition method of function sequence in space of C, we established dynamic test voltage, current and power function sequence models. Then a time-process oriented model of ternary amplitude shift keying(TASK) dynamic testing power was proposed, which given a TASK dynamic power generation plan. Based on the TASK power model, a variety of dynamic power modes both in uni-directional power and bi-directional power were proposed. Finally, a dynamic error testing system of electricity meters was constructed. Some electricity meters from different manufacturers are tested in the provided testing system, and the test results were given.
出处 《中国电机工程学报》 EI CSCD 北大核心 2016年第18期4847-4853,5108,共7页 Proceedings of the CSEE
基金 国家自然科学基金项目(51577006) 冀北电力有限公司科研项目(8ke000m15006) 黑龙江电科院项目(黑电科信[2014]190)~~
关键词 电能表 动态测试 功率模型 动态误差 electricity meter dynamic testing power model dynamic error