期刊文献+

制冷工业用蒸发器低温低应力工况分析

Low Temperature Combined with Low Stress Analysis for Refrigeration Evaporator
原文传递
导出
摘要 在制冷工业用蒸发器的设计过程中,应首先按设计温度、设计压力进行强度及应力校核,然后在最低使用温度(加50℃后,应高于-20℃)和相应的饱和压力下进行低温低应力工况的强度计算及应力校核,以确定不必遵守低温压力容器的相关规定,以达到降低成本、缩短工期、保护用户利益和增强企业竞争力的目的。为低温低应力工况压力容器的设计提供可供借鉴的经验。 During the process of the design for evaporator in refrigeration industry, it should be calculated for strength and stress by design temperature and pressure at first, then it should be executed by the saturated pressure corresponding to the lowest application temperature (which add 50℃ should be greater than -20℃), so that the design can be confirmed which don' t complied with low temperature vessel By reason of the analysis, the cost is debased, the time limit is shortened, the user benefit is protected, and the corporation competition is enhanced. It provides reference for the design of pressure vessel under the low temperature combined with low stress.
作者 赵鹏
出处 《中国化工装备》 CAS 2016年第2期37-38,42,共3页 China Chemical Industry Equipment
关键词 蒸发器低温低应力工况 制冷工业强度计算 应力校核 evaporator low temperature combined with low stress refrigeration industry strength calculation stress check
  • 相关文献

参考文献2

二级参考文献4

  • 1TSGR0004-2009,固定式压力容器安全技术监察规程[S].
  • 2GBl50.1-150.4-2011,压力容器[S].
  • 3寿比南,杨国义,徐峰,谢铁军.GBl50-2011《压力容器》标准释义[M].北京:新华出版社,2012.
  • 4HG20585-2011,钢制低温压力容器技术规定[S].

共引文献6