摘要
文章针对国电达州发电有限公司300 MW机组1#主汽门在运行中出现的卡涩问题,根据多方面调整试验,分析论证了主汽门卡涩的原因,并提出了解决办法,收到了良好的效果,保证了机组的安全经济运行。
This paper aimes at the jam problem of Dazhou Power Co., Ltd., 300 MW unit l# main steam valve in operation. According to the adjusting test, the jam reason of main steam valve is analyzed, the solution and measure for prevention are put forward, the good effect has been received, the safe and economic operation of the unit is ensured.
作者
刘新国
刘冰
Liu Xinguo Liu Bing(Guodian Dazhou Power Generation Co., Ltd., Sichuan Dazhou, 635066 Dazhou Vocational and Technical College, Siehuan Dazhou, 635001)
出处
《东方汽轮机》
2016年第3期75-77,共3页
Dongfang Turbine
关键词
主汽门
卡涩
main steam valve, jam