双级动叶可调轴流式引风机振动故障分析与处理 被引量:10

Vibration Fault Analysis and Processing of Two-Stage Adjustable Moving Blade Draft Fan
下载PDF
导出
摘要 针对某电厂双级动叶可调轴流式引风机振动大故障,结合该型式引风机结构特点,进行了振动测试,并根据测试所得各轴承的振动数据,分析认为该引风机的两级动叶存在质量不平衡。通过采用单平面动平衡处理措施,解决了该引风机的振动故障问题。 For the vibration problem of the two-stage adjustable moving blade axial flowdraft fan in a power plant, according to the structure characteristics of the draft fan, thevibration tests were performed, based on each bearing vibration data of the test result. Theanalysis showed that the two-stage blade of the draft fan was unbalanced. By using themethod of single plane balancing, the fan vibration was finally solved.
作者 俎海东 李晓波 焦晓峰 韩建春 ZU Haidong LI Xiaobo JIAO Xiaoteng HAN Jianchun(Inner Mongolia Power Research Institute, Hohhot 010020, China)
出处 《内蒙古电力技术》 2016年第4期89-91,共3页 Inner Mongolia Electric Power
基金 内蒙古电力科学研究院2014年自筹科技项目(ZC-2014-04)
关键词 双级动叶可调轴流式引风机 振动 质量不平衡 动平衡 相位 two-stage adjustable moving blade axial flow draft fan vibration mass unbalance dynamic balance phase